11.07.2015 Views

Sustainable Building Technical Manual - Etn-presco.net

Sustainable Building Technical Manual - Etn-presco.net

Sustainable Building Technical Manual - Etn-presco.net

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

❑ Develop a strategy to implement the building-commissioning process.The ASHRAE guidelines provide a good overall model. Figure 2 illustrates a three-stepcommissioning process showing the suggested activities and responsibilities of teammembers during each step. Ensure that the commissioning strategy encompasses all ofthe necessary activities in each stage of the process.❑ Prepare the design documentation and design criteria for the HVAC system,including the following information:– The HVAC system building-commissioning design documentation form, similar tothe example shown in Figure 3;– The HVAC system design criteria; and– The HVAC system description.H VAC BUILDING–COMMISSIONING DESIGN DOCUMENTAT I O NFigure 3❑ Use these HVAC system design documents to:– Verify with the building owner or users the occupants’ anticipated building programrequirements and their planned activities and equipment;– Verify the fire- and life-safety code requirements for the number of occupants; and– Verify with the mechanical engineer the ventilation requirements for the occupantsand their equipment so the HVAC system is designed with sufficient capacity to provideoutside air for the projected building population and the anticipated heat-producingequipment.❑ Have the design team and building operators review the documents to confirmthat the building is properly designed for its intended uses.The building population and equipment should not be increased beyond the designlimits for the HVAC system.❑ Prepare design documentation and design criteria for the other building systemsto be commissioned according to the format used for the HVAC system.❑ Prepare specifications to describe the commissioning process.The commissioning process should be described in the Division 1 sections of ConstructionSpecification Institute (CSI) documents (see “Specifications,” Chapter 17, for additionalinformation). The Division 1 sections should also refer the user to the appropriate technicalsections for additional information about each system’s commissioning details.❑ Specify facility startup amount in the commissioning section of Division 1 specifications.The facility startup amount is the total dollar amount that the project sponsor allocatesto commissioning in the project specifications and is released to the contractor at

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!