PRICE SCHEDULE (INDIAN BIDDERS)Schedule of Quantities for 18” dia Rewari - Kanpur Cross Country Pipeline ( Part II)176 PIPE SUPPORT suppy,erecPIPE SUPPORTS: Supply, Fabrication and erection of pipe/equipment supports (for all sizes/thickness) including shoes, pipes, cradles,turn buckles, t-posts for all types of guides, anchors, special supports for all types of pipes etc. If applicable, all necessary equipments,consumables, labour etc. for <strong>com</strong>pleting all works including supply of bolts, nuts, washers, U-clamp, wooden blocks etc. as required forsupporting supply including the cost of surface preparation by blast cleaning to SA 2.5, primer and painting all <strong>com</strong>plete as per specification,data sheets, drawings, terms and conditions and as directed by the Engineer-in-charge.Kg 1500CS Structural SteelPAINTINGSupply and application of Paint including Surface preparation blast cleaning, supply of paints, solvents and primers, and application of primerand finish paints suitable for project specific environment as defined in contract documents and on pipes as per standard specification forpainting and protective coating as per attached specification no.MH2145-C000-PI-SPC-004, indentification, lettering / Numbering, colourcoading etc. as specified including rub down and touch up wherever required and providing of scaffolding for all heights, labour, materials,tools and tackles, consumable, supervision etc. to <strong>com</strong>plete the work in all respect as per specification, Drawings, standards and instructionsof Engineer-in -charge.177178179180181182Paiting abvgrd pipe 3/4"Paiting abvgrd pipe 1"Paiting abvgrd pipe 2"Paiting abvgrd pipe 4"Paiting abvgrd pipe 6"Paiting abvgrd pipe 16"Painting of all above ground piping including all fittings, flanges etc. including colour bands Size 3/4 INCH , Painting Environment NormalCorrosive ,Painting of all above ground piping including all fittings, flanges etc. including colour bands Size 1 INCH , Painting Environment NormalCorrosive ,Painting of all above ground piping including all fittings, flanges etc. including colour bands Size 2 INCH , Painting Environment NormalCorrosive ,Painting of all above ground piping including all fittings, flanges etc. including colour bands Size 4 INCH , Painting Environment NormalCorrosive ,Painting of all above ground piping including all fittings, flanges etc. including colour bands Size 8 INCH , Painting Environment NormalCorrosive ,Painting of all above ground piping including all fittings, flanges etc. including colour bands Size 16 INCH , Painting Environment NormalCorrosive ,M2 10M2 20M2 115M2 70M2 50M2 240ALL GENERAL CIVIL WORKS AND BUILDING WORKS AS MENTIONED BELOW COMPLETE FOR SV STATION : SV-07, 08, 09, 10,11 & SAIYYADPUR PRANGENERAL CIVIL WORKS :Design, carrying out geotechnical survey and topographical survey, detail engineering, preparing construction and fabrication drawings,obtaining approval of drawings and designs from engineer-in-charge, and construction of all general civil works viz. land development, sitegrading involving cutting and filling (upto a depth of 1.2m) as per actual site conditions. <strong>com</strong>pound wall (upto a length of 180 mts), gates,approach road (with bitumen topping) from existing road (upto 50 sq. m surface area) , internal roads, drains, culverts, road crossings forelectrical and instrumentation cables, pavements, footpath, drinking water system, plumbing work for toilets, construction of tube wellincluding supply and installation of submersible pump, obtaining approval for tubewell from the statutory authorities, structural cage for allvalves including preparing design and drawing as per actual site details of valves, water harvesting system, and other miscellaneous works atSV Stations & Saiyyadpur Pran including supply of labour, material, equipment etc <strong>com</strong>plete as per specification, preliminary and conceptualdrawings, design basis, approved drawings, codes and standards, other terms and conditions and as per the direction of engineer-incharge.(DOC.NO.MH2145-C000-CI-SOW-0002)BUILDING WORKS :Design, detailed engineering, preparing construction and fabrication drawings, obtaining approval of drawings and designs from the engineerin-charge,construction of structural and architectural works for civil buildings and other miscellaneous structures, transportation, erection,fabrication, painting, finishing etc., all <strong>com</strong>plete to make ready for <strong>com</strong>missioning including switchgear & control room building for all SVstations & Saiyyadpur Pran as indicated in the attached layout plans, including supply of all labour, material, equipment etc., <strong>com</strong>plete as perspecification, preliminary and conceptual drawings, design basis, approved drawings, codes and standards, other terms and conditions and asper the direction of Engineer-in-charge.REFERENCE DOCUMENTS :1) SCOPE OF WORK : DOC.NO. : MH2145-C000-CI-SOW-00022) ARCHITECTURAL SPECIFICATION : DOC.NO. MH2145-C000-AR-SPC-0001 TO 00043) ARCHITECTURAL DESIGN BASIS : DOC.NO. MH2145-C000-AR-BOD-00014) CIVIL/STRUCTURAL SPECIFICATION : DOC.NO.MH2145-C000-CI-SPC-0001 TO 0012 & MH2145-C000-ST-SPC-0001 TO 00025) CIVIL/STRUCTURAL DESIGN BASIS : DOC.NO. MH2145-C000-CI-BOD-00016) SV SUILDING TYPE-1 (SV-01, 02, 03 04, 05, 06) STATION- ARCHITECTURAL DRAWINGS( GROUND FLOOR & ROOF PLAN,ELEVATIONS & SECTIONS, FINISHES SCHEDULE) : MH2145-C000-AR-DSK-0001 TO 00037) ARCHITECTURAL STANDARD DRAWINGS : MH2145-C000-AR-DST-0001 TO 00048) CIVIL/STRUCTURAL STANDARD DRAWINGS : MH2145-C000-CI-DST-0001 TO 0008 & MH2145-C000-ST-DST-0001, 0002 & 00049) GENERAL CIVIL LAYOUT FOR SV STATION SV STATION (SV-01,02,03,04,05,06) : MH2145-C130-CI-DGA-0001All the above for SV station/ IP station land acquired by HPCL, including obtaining approvals from concerned road authority for laying ofapproach road to SV stations/ IP Stations from the nearest road, preparation of layout plan of stations showing outside roads etc.obtaining thepermission of local authorities for construction of SV station/ IP Station building all <strong>com</strong>plete as per the scope of work, provisions of contractdocument and directions of Engineer-in-Charge.183 SV7 STATION WORKS For SV-7 station @ approx. Ch: 256.251 ,Village: Husainpur Garhia LS 1184 SV8 STATION WORKS For SV-8 station @ approx. Ch: 322.473, Village: Keshapur Rahin LS 1185 SV9 STATION WORKS For SV-9 station @ approx. Ch: 343.701, Village: Karathu LS 1186 SV10 STATION WORKS For SV-10 station @ approx. Ch: 371.453, Village: Sayal LS 1187 SV11 STATION WORKS For SV-11 station @ approx. Ch: 408.130, Village: Laipur LS 1188 For IP station @Ch: 284.605, Saiyyadpur Pran LS 1ISP STATION WORKSAll the above Including acquisition of Land in the name of HPCL for SV Stations/ IP Stations along the pipeline route at chainage marked inthe alignment sheets and as per the scope defined in Scope of Work document No. 513-MH2145-PL-SOW-0001, collection of revenuerecords, establishing correctness of ownership by search/revenue records, nil encumbrances, expediting subsequent formalities includingsigning of agreements or sale deed, if any, to facilitate possession of land by HPCL, Making payment to land owners, obtaining all requiredapprovals/no objection certificates from concerned authorities like village panchayats or municipalities etc. under whose jurisdiction each plotof land falls, for constructing and setting up the SV Stations/ IP Stations, obtaining approvals from concerned road authority for laying ofapproach road to SV stations/ IP Stations from the nearest road, registering the land in HPCL’s name including entry of HPCL’s name inoriginal Jamabandi on the acquired plot no. and obtaining copy of the same in support. Statutory fees as applicable like stamp duty etc.shallbe paid by HPCL. Prepare layout plan of station showing outside roads etc. all <strong>com</strong>plete as per the scope of work, provisions of contractdocument and directions of Engineer-in-Charge. Typically the area required for each SV station is approx. (50m X 40m) and IP station isapprox. (80m X 50m). Payment shall be made basis per Sq.m of SV/ IP land189 SV7 WORK WITH LAND Acquisition of land for SV-7 station @Ch: 256.197, Husainpur Garha (Chainage tolerance of +/- 1000 mtrs) Sq.m 2400190 SV8 WORK WITH LAND Acquisition of land for SV-8 station @Ch: 322.540, Keshapur Rahin (Chainage tolerance of +/- 500 mtrs) Sq.m 2400191 SV9 WORK WITH LAND Acquisition of land for SV-9 station @Ch: 343.670, Karathu (Chainage tolerance of +/- 1000 mtrs) Sq.m 2400192 SV10 WORK WITH LAND Acquisition of land for SV-10 station @Ch:371.453, Sayal (Chainage tolerance of +/- 1000 mtrs) Sq.m 2400193 SV11 WORK WITH LAND Acquisition of land for SV-11 station @Ch: 408.130, Laipur (Chainage tolerance of +/- 1000 mtrs) Sq.m 2400194 IPS WORK WITH LAND Acquisition of land for IP station @Ch: 284.605, Saiyyadpur Pran (Chainage tolerance of +/- 500 mtrs) Sq.m 4800195196197SV station fill grad <strong>com</strong>paSV const <strong>com</strong>pund wallSV approach roadFilling, grading & <strong>com</strong>paction of earth to finish grade level all <strong>com</strong>plete as per the specifications, approved drawings, directions of Engineer-inchargeCu.m 12000and provisions of contract document all <strong>com</strong>plete for a depth of filling over and above 1.2 m and upto 3.0mConstruction of Compound wall for SV stations/ IP Stations all <strong>com</strong>plete as per the specifications, approved drawings, scope of work,directions of Engineer-in-charge & provisions of contract document for a length over and above 180 mtrs (being paid under the earlier items) Mtrs 500Payment shall be made on length of the <strong>com</strong>pound wallConstruction of approach road (including bitumen topping) all <strong>com</strong>plete as per the specifications, approved drawings, scope of work, directionsof Engineer-in-charge and provisions of contract document for Black top surface over and above 50 Sq.m (being paid under earlier items) Sq.m 2500All related civil and structural works for scraper launcher ,receiver, pipe sleeper and miscellaneous pipe supports at Saiyyadpur Pran station &Kanpur station.SUPPORTS AND EQUIPMENT FOUNDATIONS :Design, detailed engineering, preparing construction and fabrication drawings, obtaining approval of drawings and designs from engineer-incharge,construction of supports and foundations, pipe sleepers, transportation, erection, fabrication, painting, finishing etc., all <strong>com</strong>plete forthe scraper launcher and receiving facilities of cross-country pipeline as indicated in the scope drawings, including supply of all labour,material, equipment etc. <strong>com</strong>plete as per specification, preliminary and conceptual drawings, design basis, approved drawings, codes andstandards, other terms and conditions and as per the direction of Engineer-in-charge.EXCAVATION AND BACK FILLING198Excav back fill upto 1.5mExcavation and backfilling around foundation and trenches/pits in all types of soil viz. earth, sand,gravel, clay, soft & hard murum etc.(excluding soft/hard rock) for footings, steps, plinth beams, equipment foundations, drains, trenches,manholes, underground tanks/pits, etcincluding shoring strutting, dewatering where required (until foundation work is <strong>com</strong>plete). item also includes carting of surplus excavatedearth, stacking,spreading, levelling and <strong>com</strong>pacting/consolidating surplus materials within hpcl's premises or outside at an unobjectionableplace for all leads as per instructions of WP / HPCL engineer in charge (rate includes removal of any vegetation, small shrubs etc. having girthof 300mm or less). excavated volume as per approved drawing shall only be considered for measurement.Note 1: Top soil to be cleared of shrubs grass etc including roots and 150 mm top soil to be stored separately within HPCL's premises oroutside for all leads and to be used for micrograding as required.Note 2 : Rate shall be inclusive of all royalties / obtaining clearance of local authoraties and no extra cost whatsoever than the quoted ratesshall be paid by HPCL.Up to & including 1.5 m below FGL/NGLCu. M 220CONCRETE AND ALLIED WORKSNote: The rates for all items covered in this section shall include cost of dewatering, if required till <strong>com</strong>pletion of works upto ground level andchamphers in rcc works shall be provided wherever required at no extra cost. rate of concrete work shall be inclusive of materials such ascement, sand, aggregates, water, admixtures, etc.PCC - Providing & laying plain cement concrete (nominal mix) conforming to is:456-2000, using specified graded coarse aggregate of199 PCC and allied workCu. M 7approved quality at various locations etc. including machine mixing, shuttering, consolidating with rammers/ vibrators & curing etc. <strong>com</strong>pleteas directed and instructed by WP / HPCL engineer in charge.Same as above for 1:4:8 grade concrete with 40mm max. size & down graded aggregate in making good soft & loose strata met underfoundations, base slab, plinth beams, walls & rafts etc.Page 6 of 9
PRICE SCHEDULE (INDIAN BIDDERS)Schedule of Quantities for 18” dia Rewari - Kanpur Cross Country Pipeline ( Part II)RCC - Providing & laying in position controlled grade reinforced cement concrete conforming to is:456-2000,with design mix of required gradeat all locations and levels using 20mm and down size graded aggregates in all types of works [including leaving pockets, placing of conduits,making openings, pockets placing inserts/ sleeves in columns/ beams/ slabs etc.] machine mixing, using admixtures are required, lifting,placing, machine vibrating, tamping, curing etc. as specified, <strong>com</strong>plete as per drawings & / or as directed by WP / HPCL engineer incharge.ready mix concrete may be used by contractor with concrete having required quality at no extra cost.200 RCC for m30 gradeNote: (1) The rate also includes cost of providing offsets, cutouts, formwork, construction joints, making holes in or cutting formwork for taking Cu. M 31out dowel bars, hacking the exposed surfaces to receive plaster as necessary.(2) rate of providing and fixingreinforcement steel and any other embedded steel items shall be measured and paid seperately.Same as above, but for M30 grade concrete for below ground works for footings/foundations, plinth beams, raft slabs, pedestals, trenches,manhole pit, culverts, drains, sumps, pits equipment foundations, encasing of pipes etc at depth below and upto plinth level.201RCC for m20 gradeProviding, supplying & casting in place RCC M20 grade slab/paving with all required machinaries/accessories by using vacuum dewateringmethod (tremix flooring or equivalent) inclusive of shuttering,all construction, isolation, expansion joints & tests,curing, etc <strong>com</strong>plete asdirected by WP/HPCL engineer in charge. The reinforcement shall be paid separately.Cu. M 130REINFORCEMENT-Providing, laying & fixing in position reinforcement as per dwg. locations & levels including bar bending schedules &obtaining their approval, cutting, bending & binding with 16g MS annealed binding wire incl. placing proper concrete cover blocks, chair202 Reinforcement HYSD IS1786MT 13supports etc <strong>com</strong>plete as specified and directed by wp/hpcl engineer in charge.HYSD conforming to IS:1786 of Grade Fe415Anchor bolts and relevant accessories like plates, nuts, pipesleeves etc. bolts shall be turned from M.S. rounds conforming to IS 2062 and IS432 grade 1. Nuts and washers shall conform to IS 1363 and IS 3138. Threading shall be coarse conforming to IS 1367 and IS 4218, sleeves203 Anchor boltingMT 1shall be M.S. tubes – medium to IS 1239.Embedded insert plates, insert/corner angles/channels, pipesleeves alongwith lugs/holdfast including painting as per painting specifications for204 Enbedded insert platessteel structures. Plate/angle/channels shall be conforming to IS 2062. Lugs shall be M.S. rounds conforming to IS 2062 and IS 432 Grade 1. MT 1.5205Prv & Lay Non srink groutProviding and laying non-shrink premix type grout (Fosroc or equivalent make) having minimum <strong>com</strong>pressive strength of 40N/mm2 includingproviding necessary formwork as required.Cu. M 3STRUCTURAL STEEL AND ALLIED WORKS206 STRUCTURAL STEEL & ALLIEDProviding, fabricating, welding and/or bolting, as required, erecting and fixing in position all types of structural steel works (including paintingas per specifications : MH2145-C000-CI-SPC-0005) viz. columns,beams, monorails, rafters, trusses, purlins,frame for louvres, bracing,ladders and cage ladders, sag rods (except cheqd. plates, grating & pipe railing only) made up of rolled & built up sections with moment orshear connections, shop/site fabricated including all accessories viz. nuts, bolts, cleats, gussets, suspenders etc as per specification <strong>com</strong>pleteas directed by WP/ HPCL Engineer incharge. The rate to include for welding weights, site connection, nut & bolts and same will not bemeasured for payment.(painting & sand blasting shall be included in this item.) The rate shall include for preparing & providing detailedfabrication drawings based on design drawings & getting the same approved from the WP / HPCL Engineer incharge.MT 10207Electrical System for SV's208Electrical System for IPS209Laying 11KV Power supply211Laying 11KV beyond 3kms212 TCP213 PCPElectrical SystemContractor to quote for the lump sum amount for the Residual design , supply, Installation, testing, <strong>com</strong>missioning of <strong>com</strong>plete ElectricalSystem including Transportation to site, Loading, unloading, Storage, packing, unpacking etc. at site of Electrical Equipments & accessioriesall <strong>com</strong>plete as per detailed scope of work ( MH2145-C000-EL-REQ-0009 ), specifications, design basis, data sheets, SLDs, other provisionsof contract document and directions of Engineer-In-ChargeElectrical system for SV-07,08,09,10,11Electrical system for IP Station at Saiyyadpur PranLaying of 11KV power supply line from the point of supply identified / approved by State Electricity Board / Owner to the SV/IP station ( OHline upto a maximum distance of 3Kms) including supply & installation of two pole structures, Transformer, CT/PT etc.as per the approveddrawings, schematics including supply of all material from approved vendors, installation, terminations at all ends including switchgear end,testing and Commissioning as per the scope of work, specifications and provisions of the contract document, instructions of Engineer-in-Charge and terms & conditions of SEB approval.All the works as above for any distance over & above 3Kms all <strong>com</strong>plete as per the scope of work, specifications and provisions of the contractdocument, instructions of Engineer-in-Charge and terms & conditions of SEB approval.Cathodic Protection SystemTemporary Cathodic Protection(T-C-P) system ( scope as per Annexure 1 and 2 of Scope of Work -Electrical) for Ch 227.706 to EndReceiving Station at KanpurPermanent Cathodic Protection(P-C-P) system ( scope as per Annexure 1 and 2 of Scope of Work - Electrical) for Ch 227.706 to EndReceiving Station at Kanpur, including identification & provision of anode beds including acquisition of land (in the name of HPCL) for AnodeBeds (each approx. 10 m X 10 m) including land development site / area grading as required all <strong>com</strong>plete as per the Scope of Work,Specifications, Provisions of Contract document and directions of Engineer-In-ChargeNote: Contractor to decide the locations and the TCP/PCP requirements for chainage 227.706 to End Receiving Station at KanpurLUMP5SUMLUMP1SUMLUMP6SUMMtr 10000LUMP1SUMLUMP1SUM214 Prssure gauges Bourdon215 Pressue indicating Trans216 Temp Element & trans217 Temp Element & transInstrumentation SystemPRESSURE GAUGE -Type : BOURDON TUBEInstallation & Calibration of Line mounted or Remote mounted Pressure Gauge with Pulsation Dampener / Syphon / Overrange Protector(Wherever required) inclusive of mounting of instrument, Installation of tubing materials such as valves fittings, pipes, tubes, <strong>com</strong>pressionfittings as per specification, erection of support, mounting on support, (if support required), laying of capillary on supports and installation ofmanifolds/ impulse lines with supports and tubings with SS <strong>com</strong>pression fittings as per specification No. MH2145-C000-IC-SPC-006 /MH2145-C000-IC-SPC-0017 including the cost of all labour, materials, equipment etc. as per specifications, drawings, codes and standardsand as directed by the Engineer-in-charge.PRESSURE INDICATING TRANSMITTERInstallation & Calibration of Pressure Transmitters including mounting on Yoke / Surface, piping & tubing materials such as valves, fittings,pipes, tubes, <strong>com</strong>pression fittings, supports for capillary (if any) , erection of supports for impulse lines whenever required, installation ofmanifolds/ impulse lines with supports an tubings with SS <strong>com</strong>pression fittings as per specification No. MH2145-C000-IC-SPC-006 /MH2145-C000-IC-SPC-0017 including the cost of all labour, materials, equipment etc. as per specifications, drawings, codes and standardsand as directed by the Engineer-in-charge.TEMPERATURE ELEMENT WITH TEMPERATURE TRANSMITTER-Type :Skin Temperature measurementInstallation & Calibration of RTD element along with Temperature Transmitter remote mounted. Installation of transmitter including mountingon yoke, fabrication and erection of supports with clamps and laying of extension/RTD cable, Yoke and Calibration as per specification No.MH2145-C000-IC-SPC-006 / MH2145-C000-IC-SPC-0017 including the cost of all labour, materials, equipment etc. as per specifications,drawings, codes and standards and as directed by the Engineer-in-charge.TEMPERATURE ELEMENT WITH TEMPERATURE TRANSMITTERInstallation & Calibration of RTD element with thermowell, along with Temperature Transmitter remote mounted. Installation of transmitterincluding mounting on yoke, fabrication and erection of supports with clamps and laying of extension/RTD cable, Yoke and Calibration as perspecification No. MH2145-C000-IC-SPC-006 / MH2145-C000-IC-SPC-0017 including the cost of all labour, materials, equipment etc. as perspecifications, drawings, codes and standards and as directed by the Engineer-in-charge.nos. 16nos. 15nos. 13nos. 2218 Inst Thermal relief valve219 Inst&Calb wall heat detect220 Inst&Calb smokedetect opt221 Inst&Calb smokedetect ion222 Inst&Calb Hydrogen detect223 Inst&Calb MCP224 Inst&Calb audio alarm225 Inst&Calb audio alarm226 FIRE ALARM PANEL, RTU227 Supply FAS equipment228 Extra Depth bet. 2 to 5 mtrNOTE:1NOTE:2NOTE:3THERMAL RELIEF VALVEInstallation of TSV on piping / vessel with or without isolation valves as per requirement ,Installation of valve including fabrication and erectionof supports with clamps and Calibration. including the cost of all labour, materials, equipment etc. as per datasheet no, (Doc no. MH2145-C000-IC-DAS-0002) drawings, codes and standards and as directed by the Engineer-in-charge.Installation & Calibration of wall mounted heat detector-Type: Rate of rise Heat, 24V DC, 4-20mA O/p, Safe Area, IP 42 (minimum)As per Specification no. MH2145-C000-00-IC-SPC-0009.Installation & Calibration of wall mounted smoke detector-Type: Optical Type Smoke, 24V DC, 4-20mA O/p, Safe Area, IP42 (minimum).As per Specification no. MH2145-C000-00-IC-SPC-0009.Installation & Calibration of wall mounted smoke detector-Type: lonisation Type Smoke, 24V DC, 4-20mA O/p, Safe Area, IP42 (minimum).As per Specification no. MH2145-C000-00-IC-SPC-0009.Installation & Calibration of Hydrogen Gas Detector for Battery Room.As per Specification no. MH2145-C000-00-IC-SPC-0009.Installation & Calibration of Manual Alarm Call Point double action "break glass" unit.As per Specification no. MH2145-C000-00-IC-SPC-0009.Installation & Calibration of Visual Alarm 24VDC,IP66,Explosion proof ,ZONE-1,ISAs per Specification no. MH2145-C000-00-IC-SPC-0009.Installation & Calibration of Audio Alarm 4VDC,IP66,Explosion proof ,ZONE-1.As per Specification no. MH2145-C000-00-IC-SPC-0009.FIRE ALARM PANEL, RTU, TELECOMMUNICATION SYSTEM: Erection of Units suppiled by vendors of Tele<strong>com</strong>, SCADA packages,including supply & laying of cables laying as per the approved cable layout between indoor units and from field instruments to indoor unitsincluding cable terminations as required, all necessary assistance to package vendors for Testing & Commissioning all <strong>com</strong>plete as per thescope of work, specifications and directions of Engineeer-in-ChargeSUPPLY OF FIRE FIGHTING & SAFETY EQUIPMENTRESIDUAL DESIGN, ENGINEERING, MATERIALS, FABRICATION, ASSEMBLY, INSPECTION, TESTING, PAINTING,DOCUMENTATION, SUPPLY AND SHIPMENT OF ALL ITEMS LISTED UNDER SCOPE OF WORK DOCUMENT NO ."MH2145-C000-SR-SOW-0001", Specifications, Data Sheets, provisions of the contract document and directions of Engineer-In-Charge. The item shall alsoinclude placement of all the equipment as per approved equipment arrangement drawing / layoutAdditional rate over pipeline laying described under line no. 110,111,112,113 & 114 with extra clearcover of 2m to 5m beyond that defined inthe alignment sheet for single approved stretch beyond 150m pre-approved by site-in-charge based on site condition.All fire extinguishers shall conform to respective IS/UL or Equivalent codes, viz. 10 Kg DCP Type (applicable IS:/UL Standard), 4.5/6,8 KgCO2 Type (IS:2878/UL 154) & 25/50/75 Kg DCP Type (IS:10658/UL 299) and bear ISI/UL markSafety Equipment / CO2 flooding system shall meet OISD / NFPA requirement and shall bear relevant/required IS/UL markSafety Signages shall be supplied as lot item based on site requirements.nos. 8nos. 18nos. 36nos. 24nos. 6nos. 24nos. 24nos. 30nos. 6NOS. 6Meters 3000Page 7 of 9
- Page 1 and 2:
Hindustan Petroleum Corporation Ltd
- Page 3 and 4:
CHAPTER 1REQUEST FOR QUOTATION (RFQ
- Page 5 and 6:
Local ConditionsIt will be imperati
- Page 7:
The tender details including EMD, B
- Page 10 and 11:
his bid shall not be considered for
- Page 12 and 13:
5) This prime member shall be solel
- Page 14 and 15:
Note:1. All the information require
- Page 16 and 17:
EMD submitted by the bidder for sub
- Page 18 and 19:
however, bids in hard copies shall
- Page 20 and 21:
7.0 A firm which is not a PSU or an
- Page 22 and 23:
We are unable to bid for the reason
- Page 24 and 25:
CUT-OUT SLIPDO NOT OPEN- THIS IS A
- Page 26 and 27:
CUT-OUT SLIPDO NOT OPEN- THIS IS A
- Page 28 and 29:
QUOTATION AGAINST TENDERENQUIRY (En
- Page 30 and 31:
INDEXSR. NO.ARTICLE DESCRIPTION1.0
- Page 32 and 33:
modify the Bid Document. The amendm
- Page 34 and 35:
sealed and pasted with the enclosed
- Page 36 and 37:
l. Declaration with the bid qualifi
- Page 38 and 39:
Fax:91-22-67818080 in the presence
- Page 40 and 41:
for Part-II. In case such bidder is
- Page 42 and 43:
In case if the bidder quotes the ra
- Page 44 and 45:
xv)xvi)xvii)Non Submission of decla
- Page 46 and 47:
(c)When it is not possible to ascer
- Page 48 and 49:
14.7.2 To offset Central Sales Tax
- Page 50 and 51:
Where based on workability assessme
- Page 52 and 53:
tender terms not in deviation sheet
- Page 54 and 55:
INDEXSr. No. Article Description1.
- Page 56 and 57:
GENERAL TERMS & CONDITIONS OF CONTR
- Page 58 and 59:
2. 8 The "Drawings" shall include m
- Page 60 and 61:
3.6 The quantities indicated in the
- Page 62 and 63:
wherever required in the tender pap
- Page 64 and 65:
For working on Sundays/Holidays, th
- Page 66 and 67:
5.b COMMENCEMENT OF WORKThe contrac
- Page 68 and 69:
Contractor or the BG (if LD is full
- Page 70 and 71:
manufacture or fabrication or on th
- Page 72 and 73:
a. defects, if any, to be rectified
- Page 74 and 75:
payment of wages, salaries or other
- Page 76 and 77:
6.e.INSURANCE AND LABOURContractor
- Page 78 and 79:
iv. The contractor shall ensure tha
- Page 80 and 81:
7. PAYMENT OF CONTRACTOR'S BILLS7.
- Page 82 and 83:
shall be final and binding on the C
- Page 84 and 85:
7.e.4.Manufacturer's certificate sh
- Page 86 and 87:
accordance with the contract, the C
- Page 88 and 89:
12.0 TERMINATION OF CONTRACT12.1 Th
- Page 90 and 91:
Contractor to complete the job with
- Page 92 and 93:
shall be entitled at any time to in
- Page 94 and 95:
INDEX1. DEFINITION2. REFERENCE FOR
- Page 96 and 97:
and scope of work (technical), GPC
- Page 98 and 99:
In order to facilitate over-all exe
- Page 100 and 101:
Dimensions :For every order and eve
- Page 102 and 103:
26. CHANGESThe Owner has the option
- Page 104 and 105:
34. TECHNICAL INFORMATIONDrawings,
- Page 106 and 107:
Chapter: 4SPECIAL CONDITIONSOFCONTR
- Page 108 and 109:
44.0 DRAWINGS AND DOCUMENTS45.0 HOU
- Page 110 and 111:
viii) General Terms & Conditions of
- Page 112 and 113:
duties levied by statutory authorit
- Page 114 and 115:
stipulations including obtaining re
- Page 116 and 117:
4.1.3 Unless otherwise stated the t
- Page 118 and 119:
4.2.6 No Interest charges for delay
- Page 120 and 121:
9.0 PROVIDENT FUND, LABOUR, LABOUR
- Page 122 and 123:
not carried out work according to g
- Page 124 and 125:
16.a7 The Arbitrator may give a com
- Page 126 and 127:
19.0 Mobilization Advance19.1 Contr
- Page 128 and 129:
persons/persons or bodies/companies
- Page 130 and 131:
CONTRACTOR shall take all precautio
- Page 132 and 133:
Employer/Consultant shall not provi
- Page 134 and 135:
and return to the Contractor the st
- Page 136 and 137:
the work as per standards and all c
- Page 138 and 139:
42.0 COORDINATION WITH OTHER AGENCI
- Page 140 and 141:
pipelines, cables etc., during cons
- Page 142 and 143:
Engineer-in-charge during execution
- Page 144 and 145:
56.2 All the tests either on the fi
- Page 146 and 147:
The information to possible extent
- Page 148 and 149:
in part or in full.e) Functional Sc
- Page 150 and 151:
OWNER.66.4.4 Progress reports shall
- Page 152 and 153:
Order, or material of sub-standard
- Page 154 and 155:
75.11 Co-ordination with appropriat
- Page 156 and 157:
81.2 Contractor shall develop and s
- Page 158 and 159:
y them / Vendors shall be provided
- Page 160 and 161:
Contractor to note that it is their
- Page 162 and 163:
3.0 APPENDICES TO SCCMH2145-C000-PS
- Page 164 and 165:
SCOPE OF WORK & SUPPLY(APPENDIX-I t
- Page 166 and 167:
MATHURARKPL Project OfficeHPCL Depo
- Page 168 and 169:
12. Compensatory Afforestation as p
- Page 170 and 171:
TIME SCHEDULESr No Description Comp
- Page 172 and 173:
MEASUREMENT OF WORK(APPENDIX-III to
- Page 174 and 175:
The contractor shall submit the bil
- Page 176 and 177:
5.0 ELECTRICAL WORKS5.1 Cables5.1.1
- Page 178 and 179:
TERMS OF PAYMENT(APPENDIX-IV to SCC
- Page 180 and 181:
B) 5% on completion of all works in
- Page 182 and 183:
6.2.2 85% against completion of fou
- Page 184 and 185:
GENERAL NOTEBefore start of work, t
- Page 186 and 187:
3.1.4 The bidder shall submit, alon
- Page 188 and 189:
methodologies which he is going to
- Page 190 and 191:
Bidder’s Quality PlanPO/ Contact
- Page 192 and 193:
23Check for excessive temperature r
- Page 194 and 195:
LT MOTORSSlNo. ACTIVITY CONTRACTOR
- Page 196 and 197:
MLDB, LP AND PDBsSlNo. ACTIVITY CON
- Page 198 and 199:
PRELIMINARY CHECKS1 Check that cabl
- Page 200 and 201:
1.0 INTRODUCTION2.0 SCOPEThis docum
- Page 202 and 203:
4.4 TESTINGPrior to shop prefabrica
- Page 204 and 205:
6.0 ATTACHMENT (WAIVER/DEVIATION PE
- Page 206 and 207:
TO BE COMPLETED BY CUSTOMER ‘TECH
- Page 208 and 209:
APPENDIX -VI TO SCCHSE MANAGEMENT P
- Page 210 and 211:
INDEX1. CONDITIONS FOR ISSUE OF MAT
- Page 212 and 213:
NOTE :1)Landed Rate shall be arrive
- Page 214 and 215:
own cost to Owner's stores. In case
- Page 216 and 217:
MINIMUM NO. OF SKILLED MANPOWER (AT
- Page 218 and 219:
NOTE :-(1) The details of estimated
- Page 220 and 221:
MINIMUM EQUIPMENT DEPLOYMENT PART W
- Page 222 and 223:
22 Sand/Grit Blasting Cleaning M/c.
- Page 224 and 225:
45 GPS /GIS M/c for taking the co-o
- Page 226 and 227:
8 Excavator / Back Hoe (Ex 280/ 300
- Page 228 and 229:
31 Dead Weight Tester(Ravika 0-400k
- Page 230 and 231:
(2) Meeting the requirement of depl
- Page 232 and 233:
EXPERIENCE CRITERIA FOR KEY PERSONN
- Page 234 and 235:
1011LEAD WELDING /NDTENGINEERWAREHO
- Page 236 and 237:
1. The Labour rates are "all inclus
- Page 238 and 239:
EQUIPMENT HIRING/RECOVERY RATES(APP
- Page 240 and 241:
31. Pipe Trailers (FB / Semi Low Be
- Page 242 and 243:
INSTRUMENTS1. ELECTRONICS TRANSMITT
- Page 244 and 245:
16. SOLENOID VALVESA. AVCON CONTROL
- Page 246 and 247:
1. CENTRIFUGAL PUMPS VERTICAL - GEN
- Page 248 and 249:
G. UNIQUE INDUSTRIAL PACKINGSH. VIR
- Page 250 and 251:
K. TORMENE GAS TECHNOLOGY SPA, ITAL
- Page 252 and 253:
21. VALVE GLOBE FORGEDA. ASSOCIATED
- Page 254 and 255:
2. CABLES-CONTROL - PVCA. CCIB. FIN
- Page 256 and 257:
E. BHARTIA CUTLER HAMMER.F. CONTROL
- Page 258 and 259:
33. PERMANENT REFERENCE ELECTRODESA
- Page 260 and 261:
B. H & R JOHNSONC. BELL CERAMICSD.
- Page 262 and 263:
HINDUSTAN PETROLEUM CORPORATION LIM
- Page 264 and 265:
SR.No.A1234567BParticularsF13707 /C
- Page 266 and 267:
1 RJ/15/568 (P5322) - 24/12/2012234
- Page 268 and 269:
3NCR/GAS-O&M/DM(O&M)-152/2012/216 -
- Page 270 and 271:
2 34091/05/12-IA/728 - 3/5/2012G12H
- Page 272 and 273:
18192021222324252627282930313233342
- Page 274 and 275:
CHAPTER-5BRIEF SUMMARY OFAGREED TER
- Page 276 and 277:
(ix) Confirm acceptance of Liquidat
- Page 278 and 279:
1. Annexure-A Bid Security FormCHAP
- Page 280 and 281:
ANNEXURE-ABID SECURITY FORMBANK GUA
- Page 282 and 283:
COMPOSITE BANK GUARANTEE FOR SECURI
- Page 284 and 285:
writing.8. We, ....................
- Page 286 and 287:
ANNEXURE--DDECLARATION (NOT BANNED)
- Page 288 and 289:
ANNEXURE-FQUALIFICATION FORMAT - FO
- Page 290 and 291: ANNEXURE-GIntegrity Pact[KK1]MH2145
- Page 292 and 293: form part of this contract / supply
- Page 294 and 295: INTEGRITY PACTBetweenHindustan Petr
- Page 296 and 297: caused by him and has installed a s
- Page 298 and 299: Section 9 — Pact DurationThis Pac
- Page 300 and 301: MH2145-C000-PS-RFQ-0020Page 300 of
- Page 302 and 303: MH2145-C000-PS-RFQ-0020Page 302 of
- Page 304 and 305: Note:1. The message should be in Co
- Page 306 and 307: 3 . We ............................
- Page 308 and 309: ANNEXURE-JBANK GUARANTEE FOR MOBILI
- Page 310 and 311: 10. "The Bank" has power to issue t
- Page 312 and 313: servants and/or agents whatsoever t
- Page 314 and 315: UNDERTAKING (CORPORATE/ NON-CORPORA
- Page 316 and 317: ANNEXURE-NUNDERTAKING OF ADEQUATE C
- Page 318 and 319: 2 This Guarantee/Undertaking shall
- Page 320 and 321: Annexure-PNAME OF SUPPLY : ……
- Page 322 and 323: ANNEXURE - Q.1Business Rules for fi
- Page 324 and 325: v. After the completion of English
- Page 326 and 327: Annexure - Q.IIN.B.Terms & Conditio
- Page 328 and 329: Annexure- Q.IIIProcess Compliance F
- Page 330 and 331: Annexure Q.VCONTACT INFORMATION....
- Page 332 and 333: Annexure -SCERTIFICATE OF NON-INVOL
- Page 334 and 335: CHAPTER NO.8PRICE BID FORMATMH2145-
- Page 336 and 337: PRICE SCHEDULE (INDIAN BIDDERS)Sche
- Page 338 and 339: PRICE SCHEDULE (INDIAN BIDDERS)Sche
- Page 342 and 343: Item No. Item Description Unit Quan
- Page 344 and 345: PRICE SCHEDULE (FOREIGN BIDDERS)Sch
- Page 346 and 347: PRICE SCHEDULE (FOREIGN BIDDERS)Sch
- Page 348 and 349: PRICE SCHEDULE (FOREIGN BIDDERS)Sch
- Page 350 and 351: PRICE SCHEDULE (FOREIGN BIDDERS)Sch
- Page 352 and 353: PRICE SCHEDULE (FOREIGN BIDDERS)Sch
- Page 354 and 355: PRICE SCHEDULE (INDIAN BIDDERS)Sche
- Page 356 and 357: m No. Short description Item Descri
- Page 358 and 359: m No. Short description Item Descri
- Page 360 and 361: m No. Short description Item Descri
- Page 362 and 363: m No. Short description Item Descri
- Page 364 and 365: Item No. Item Description Unit Quan
- Page 366 and 367: UN PRICE SCHEDULE (INDIAN BIDDERS)S
- Page 368 and 369: UN PRICE SCHEDULE (INDIAN BIDDERS)S
- Page 370 and 371: UN PRICE SCHEDULE (INDIAN BIDDERS)S
- Page 372 and 373: Item No.PRICE SCHEDULE (FOREIGN BID
- Page 374 and 375: PRICE SCHEDULE (FOREIGN BIDDERS)Sch
- Page 376 and 377: PRICE SCHEDULE (FOREIGN BIDDERS)Sch
- Page 378 and 379: PRICE SCHEDULE (FOREIGN BIDDERS)Sch
- Page 380 and 381: UN PRICE SCHEDULE (FOREIGN BIDDERS)