12.07.2015 Views

Pipelaying Tender-VOL I - WorleyParsons.com

Pipelaying Tender-VOL I - WorleyParsons.com

Pipelaying Tender-VOL I - WorleyParsons.com

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

m No. Short description Item Description Unit QuantityPRICE SCHEDULE (INDIAN BIDDERS)Schedule of Quantities for 18” dia Rewari - Kanpur Cross Country Pipeline ( Part I)Unit Price inclusive of all cost towards Air/Rail fare, lodging,boarding, Traveling ,medical , localtransport, all insurances, in<strong>com</strong>e/corporate(as may be applicable) ,incidental chargesand all other expenses, taxes Itduties etc. but excluding service taxService Tax including cessapplicable onUnit Price(@ 12.36%)Total Price inclusive of all costtowards Air/ Rail fare, lodging,boarding, Traveling,medical , local transport, allinsurances, in<strong>com</strong>e/corporate (as maybe applicable),incidental charges and all otherexpenses , taxes It duties etc.including service tax(7) = (5 + 6) x 422 Inst Thermal relief valve23 Inst&Calb wall heat detectTHERMAL RELIEF VALVEInstallation of TSV on piping / vessel with or without isolation valves as per requirement ,Installation of valve including fabrication anderection of supports with clamps and Calibration. including the cost of all labour, materials, equipment etc. as per datasheet no, (Doc no.MH2145-C000-IC-DAS-0002) drawings, codes and standards and as directed by the Engineer-in-charge.Installation & Calibration of wall mounted heat detector-Type: Rate of rise Heat, 24V DC, 4-20mA O/p, Safe Area, IP 42 (minimum)As per Specification no. MH2145-C000-00-IC-SPC-0009.nos. 5nos. 1824 Inst&Calb smokedetect optInstallation & Calibration of wall mounted smoke detector-Type: Optical Type Smoke, 24V DC, 4-20mA O/p, Safe Area, IP42 (minimum).As per Specification no. MH2145-C000-00-IC-SPC-0009.nos. 3625 Inst&Calb smokedetect ion26 Inst&Calb Hydrogen detect27 Inst&Calb MCP28 Inst&Calb audio alarm29 Inst&Calb audio alarm30 FIRE ALARM PANEL, RTUInstallation & Calibration of wall mounted smoke detector-Type: lonisation Type Smoke, 24V DC, 4-20mA O/p, Safe Area, IP42 (minimum).As per Specification no. MH2145-C000-00-IC-SPC-0009.Installation & Calibration of Hydrogen Gas Detector for Battery Room.As per Specification no. MH2145-C000-00-IC-SPC-0009.Installation & Calibration of Manual Alarm Call Point double action "break glass" unit.As per Specification no. MH2145-C000-00-IC-SPC-0009.Installation & Calibration of Visual Alarm 24VDC,IP66,Explosion proof ,ZONE-1,ISAs per Specification no. MH2145-C000-00-IC-SPC-0009.Installation & Calibration of Audio Alarm 24VDC,IP66,Explosion proof ,ZONE-1.As per Specification no. MH2145-C000-00-IC-SPC-0009.FIRE ALARM PANEL, RTU, TELECOMMUNICATION SYSTEM: Erection of Units suppiled by vendors of Tele<strong>com</strong>, SCADA packages,including supply & laying of cables laying as per the approved cable layout between indoor units and from field instruments to indoor unitsincluding cable terminations as required, all necessary assistance to package vendors for Testing & Commissioning all <strong>com</strong>plete as per thescope of work, specifications and directions of Engineeer-in-Chargenos. 24nos. 6nos. 24nos. 24nos. 30nos. 631 Supply FAS equipmentSUPPLY OF FIRE FIGHTING & SAFETY EQUIPMENTRESIDUAL DESIGN, ENGINEERING, MATERIALS, FABRICATION, ASSEMBLY, INSPECTION, TESTING, PAINTING,DOCUMENTATION, SUPPLY AND SHIPMENT OF ALL ITEMS LISTED UNDER SCOPE OF WORK DOCUMENT NO ."MH2145-C000-SR-SOW-0001", Specifications, Data Sheets, provisions of the contract document and directions of Engineer-In-Charge. The itemshall also include placement of all the equipment as per approved equipment arrangement drawing / layoutSets 632 Extra Depth bet. 2 to 5 mtrAdditional rate over pipeline laying described under line no. 35,36,37 & 38 with extra clearcover of 2m to 5m beyond that defined in thealignment sheet for single approved stretch beyond 150m pre-approved by site-in-charge based on site condition.Meters 3000TE:1TE:2TE:3All fire extinguishers shall conform to respective IS/UL or Equivalent codes, viz. 10 Kg DCP Type (applicable IS:/UL Standard), 4.5/6,8 KgCO2 Type (IS:2878/UL 154) & 25/50/75 Kg DCP Type (IS:10658/UL 299) and bear ISI/UL markSafety Equipment / CO2 flooding system shall meet OISD / NFPA requirement and shall bear relevant/required IS/UL markSafety Signages shall be supplied as lot item based on site requirements.Page 9 of 18

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!