12.07.2015 Views

Pipelaying Tender-VOL I - WorleyParsons.com

Pipelaying Tender-VOL I - WorleyParsons.com

Pipelaying Tender-VOL I - WorleyParsons.com

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

m No. Short description Item Description Unit QuantityEXCAVATION AND BACK FILLINGExcavation and backfilling around foundation and trenches/pits in all types of soil viz. earth, sand,gravel, clay, soft & hard murum etc.(excluding soft/hard rock) for footings, steps, plinth beams, equipment foundations, drains, trenches,manholes, underground tanks/pits, etcincluding shoring strutting, dewatering where required (until foundation work is <strong>com</strong>plete). item also includes carting of surplus excavatedearth, stacking,spreading, levelling and <strong>com</strong>pacting/consolidating surplus materials within HPCL's premises or outside at an unobjectionableplace for all leads as per instructions of WP / HPCL engineer in charge (rate includes removal of any vegetation, small shrubs etc. having07 Excav back fill upto 1.5mCu. M 330girth of 300mm or less). excavated volume as per approved drawing shall only be considered for measurement.Note 1: Top soil to be cleared of shrubs grass etc including roots and 150 mm top soil to be stored separately within HPCL's premises oroutside for all leads and to be used for micrograding as required.Note 2 : Rate shall be inclusive of all royalties / obtaining clearance of local authoraties and no extra cost whatsoever than the quoted ratesshall be paid by HPCL.Up to & including 1.5 m below FGL/NGLPRICE SCHEDULE (INDIAN BIDDERS)Schedule of Quantities for 18” dia Rewari - Kanpur Cross Country Pipeline ( Part I)Unit Price inclusive of all cost towards Air/Rail fare, lodging,boarding, Traveling ,medical , localtransport, all insurances, in<strong>com</strong>e/corporate(as may be applicable) ,incidental chargesand all other expenses, taxes Itduties etc. but excluding service taxService Tax including cessapplicable onUnit Price(@ 12.36%)Total Price inclusive of all costtowards Air/ Rail fare, lodging,boarding, Traveling,medical , local transport, allinsurances, in<strong>com</strong>e/corporate (as maybe applicable),incidental charges and all otherexpenses , taxes It duties etc.including service tax(7) = (5 + 6) x 408PCC and allied workCONCRETE AND ALLIED WORKSNote: The rates for all items covered in this section shall include cost of dewatering, if required till <strong>com</strong>pletion of works upto ground level andchamphers in rcc works shall be provided wherever required at no extra cost. rate of concrete work shall be inclusive of materials such ascement, sand, aggregates, water, admixtures, etc.PCC - Providing & laying plain cement concrete (nominal mix) conforming to is:456-2000, using specified graded coarse aggregate ofapproved quality at various locations etc. including machine mixing, shuttering, consolidating with rammers/ vibrators & curing etc. <strong>com</strong>pleteas directed and instructed by WP / HPCL engineer in charge.Same as above for 1:4:8 grade concrete with 40mm max. size & down graded aggregate in making good soft & loose strata met underfoundations, base slab, plinth beams, walls & rafts etc.Cu. M 15RCC - Providing & laying in position controlled grade reinforced cement concrete conforming to is:456-2000,with design mix of requiredgrade at all locations and levels using 20mm and down size graded aggregates in all types of works [including leaving pockets, placing ofconduits, making openings, pockets placing inserts/ sleeves in columns/ beams/ slabs etc.] machine mixing, using admixtures are required,lifting, placing, machine vibrating, tamping, curing etc. as specified, <strong>com</strong>plete as per drawings & / or as directed by WP / HPCL engineerincharge. ready mix concrete may be used by contractor with concrete having required quality at no extra cost.99 RCC for m30 grade Note: (1) The rate also includes cost of providing offsets, cutouts, formwork, construction joints, making holes in or cutting formwork for Cu. M 50taking out dowel bars, hacking the exposed surfaces to receive plaster as necessary.(2) rate of providing andfixing reinforcement steel and any other embedded steel items shall be measured and paid seperately.Same as above, but for M30 grade concrete for below ground works for footings/foundations, plinth beams, raft slabs, pedestals, trenches,manhole pit, culverts, drains, sumps, pits equipment foundations, encasing of pipes etc at depth below and upto plinth level.09 RCC for m20 gradeProviding, supplying & casting in place RCC M20 grade slab/paving with all required machinaries/accessories by using vacuum dewateringmethod (tremix flooring or equivalent) inclusive of shuttering,all construction, isolation, expansion joints & tests,curing, etc <strong>com</strong>plete asdirected by WP/HPCL engineer in charge. The reinforcement shall be paid separately.Cu. M 195REINFORCEMENT-Providing, laying & fixing in position reinforcement as per dwg. locations & levels including bar bending schedules &obtaining their approval, cutting, bending & binding with 16g MS annealed binding wire incl. placing proper concrete cover blocks, chairsupports etc <strong>com</strong>plete as specified and directed by wp/hpcl engineer in charge.10 Reinforcement HYSD IS1786 HYSD conforming to IS:1786 of Grade Fe415 MT 2011 Anchor boltingAnchor bolts and relevant accessories like plates, nuts, pipesleeves etc. bolts shall be turned from M.S. rounds conforming to IS 2062 andIS 432 grade 1. Nuts and washers shall conform to IS 1363 and IS 3138. Threading shall be coarse conforming to IS 1367 and IS 4218,sleeves shall be M.S. tubes – medium to IS 1239.MT 112 Enbedded insert platesEmbedded insert plates, insert/corner angles/channels, pipesleeves alongwith lugs/holdfast including painting as per painting specificationsfor steel structures. Plate/angle/channels shall be conforming to IS 2062. Lugs shall be M.S. rounds conforming to IS 2062 and IS 432Grade 1.MT 1.513 Prv & Lay Non srink groutProviding and laying non-shrink premix type grout (Fosroc or equivalent make) having minimum <strong>com</strong>pressive strength of 40N/mm2including providing necessary formwork as required.Cu. M 3STRUCTURAL STEEL AND ALLIED WORKS14Providing, fabricating, welding and/or bolting, as required, erecting and fixing in position all types of structural steel works (including paintingas per specifications : MH2145-C000-CI-SPC-0005) viz. columns,beams, monorails, rafters, trusses, purlins,frame for louvres, bracing,ladders and cage ladders, sag rods (except cheqd. plates, grating & pipe railing only) made up of rolled & built up sections with moment orSTRUCTURAL STEEL & ALLIED shear connections, shop/site fabricated including all accessories viz. nuts, bolts, cleats, gussets, suspenders etc as per specification<strong>com</strong>plete as directed by WP/ HPCL Engineer incharge. The rate to include for welding weights, site connection, nut & bolts and same willnot be measured for payment, including the cost of surface preparation by blast cleaning to SA 2.5, primer and painting all <strong>com</strong>plete as perspecification, data sheets, drawings, terms and conditions and as directed by the Engineer-in-charge. The rate shall include for preparing &providing detailed fabrication drawings based on design drawings & getting the same approved from the WP / HPCL Engineer incharge.MT 2Electrical SystemContractor to quote for the lump sum amount for the Residual design , supply, Installation, testing, <strong>com</strong>missioning of <strong>com</strong>plete ElectricalSystem including Transportation to site, Loading, unloading, Storage, packing, unpacking etc. at site of Electrical Equipments &accessiories all <strong>com</strong>plete as per detailed scope of work ( MH2145-C000-EL-REQ-0009 ), specifications, design basis, data sheets, SLDs,other provisions of contract document and directions of Engineer-In-Charge15 Electrical System for SV's Electrical system for SV stations -01,02,03,04,05 & 0616 Laying 11KV Power supply17 Laying 11KV beyond 3kms18 TCP10 PCPLaying of 11KV power supply line from the point of supply identified / approved by State Electricity Board / Owner to the SV station ( OHline upto a maximum distance of 3Kms) including supply & installation of two pole structures, Transformer, CT/PT etc.as per the approveddrawings, schematics including supply of all material from approved vendors, installation, terminations at all ends including switchgear end,testing and Commissioning as per the scope of work, specifications and provisions of the contract document, instructions of Engineer-in-Charge and terms & conditions of SEB approval.All the works as above for any distance over & above 3Kms all <strong>com</strong>plete as per the scope of work, specifications and provisions of thecontract document, instructions of Engineer-in-Charge and terms & conditions of SEB approval.Cathodic Protection SystemTemporary Cathodic Protection(T-C-P) system ( scope as per Annexure 1 and 2 of Scope of Work -Electrical) for Ch 000 to Ch :227.706all <strong>com</strong>plete as per the Scope of Work, Specifications, Provisions of Contract document and directions of Engineer-in-ChargePermanent Cathodic Protection(P-C-P) system (scope as per Annexure 1 and 2 of Scope of Work - Electrical) for Ch 00 to Ch 227.706 ,including identification & provision of anode beds including acquisition of land (in the name of HPCL) for Anode Beds (each approx. 10 m X10 m) including land development site / area grading as required all <strong>com</strong>plete as per the Scope of Work, Specifications, Provisions ofContract document and directions of Engineer-In-ChargeNote: Contractor to decide the locations of Anode beds, the TCP/PCP requirements for chainage 0 to 227.706 in consultation withEngineer-in-ChargeInstrumentation SystemPRESSURE GAUGE -Type : BOURDON TUBELUMPSUMLUMPSUM66Mtr 10000LUMPSUMLUMPSUM1119 Prssure gauges Bourdon20 Pressue indicating Trans21 Temp Element & transInstallation & Calibration of Line mounted or Remote mounted Pressure Gauge with Pulsation Dampener / Syphon / Overrange Protector(Wherever required) inclusive of mounting of instrument, Installation of tubing materials such as valves fittings, pipes, tubes, <strong>com</strong>pressionfittings as per specification, erection of support, mounting on support, (if support required), laying of capillary on supports and installation ofmanifolds/ impulse lines with supports and tubings with SS <strong>com</strong>pression fittings as per specification No. MH2145-C000-IC-SPC-006 /MH2145-C000-IC-SPC-0017 including the cost of all labour, materials, equipment etc. as per specifications, drawings, codes andstandards and as directed by the Engineer-in-charge.nos. 22PRESSURE INDICATING TRANSMITTERInstallation & Calibration of Pressure Transmitters including mounting on Yoke / Surface, piping & tubing materials such as valves, fittings,pipes, tubes, <strong>com</strong>pression fittings, supports for capillary (if any) , erection of supports for impulse lines whenever required, installation ofmanifolds/ impulse lines with supports an tubings with SS <strong>com</strong>pression fittings as per specification No. MH2145-C000-IC-SPC-006 /nos. 17MH2145-C000-IC-SPC-0017 including the cost of all labour, materials, equipment etc. as per specifications, drawings, codes andstandards and as directed by the Engineer-in-charge.TEMPERATURE ELEMENT WITH TEMPERATURE TRANSMITTER-Type :Skin Temperature measurementInstallation & Calibration of RTD element along with Temperature Transmitter remote mounted. Installation of transmitter including mountingon yoke, fabrication and erection of supports with clamps and laying of extension/RTD cable, Yoke and Calibration as per specification No. nos. 17MH2145-C000-IC-SPC-006 / MH2145-C000-IC-SPC-0017 including the cost of all labour, materials, equipment etc. as per specifications,drawings, codes and standards and as directed by the Engineer-in-charge.Page 8 of 18

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!