12.07.2015 Views

Manual - AEQ International

Manual - AEQ International

Manual - AEQ International

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

2.2.6. Wiring.All wiring kits described below are optional and have been designed by <strong>AEQ</strong> to simplify theinstallation of the unit. To facilitate the quick connection of the console in almost any installation,<strong>AEQ</strong> can supply audio and data cables with the corresponding DB-type connectors that areused to connect the unit. These cables can be cut to desired lengths and soldered on patchpanels, punched into connector strips or fitted with the corresponding connectors to be useddirectly connected to the peripheral equipment.For easiest installation, CAPITOL console uses a single type of Multiconnector: female DB 15,so only two types of cable are required: data and audio. Their description (for the maximalconfiguration) is:• FR CAB INP: Male DB15 connector connected to a balanced and shielded four pair, 6-meter cable with open-end termination, for 4 audio inputs or outputs. Max 9 cables perconsole.• CP CAB GPIO: Male DB15 connector, soldered to 6-meter long multiwire (interphonetype), not terminated, for GPI, GPO or relays for CAPITOL console. Max 3 cables perconsole.<strong>AEQ</strong> can upon request provide fully finished cables and in special lengths. For more informationplease refer to <strong>AEQ</strong> sales department or authorised distributors.- FR CAB INP pinout and use.- CP CAB GPIO pinout and use.Color table GPI GPO GPO (RELAY)Wire Color Signal PIN Signal PIN Signal PIN1 Red GPI1 1 GPO1 1 GPO RL1NO 12 White GPI2 2 GPO2 2 GPO RL1NC 23 Green GPI3 3 GPO3 3 GPO RL2NO 34 Yellow GPI4 4 GPO4 4 GPO RL2NC 45 Blue GPI5 5 GPO5 5 GPO RL3NO 56 Grey GPI6 6 GPO6 6 GPO RL3NC 67 Black GPI7 7 GPO7 7 GPO RL4NO 78 Brown GPI8 8 GPO8 8 GPO RL4NC 89 Orange GPI1(Gnd 1-4) 9 GPO1(Gnd 1-4) 9 GPO RL1COM 910 Purple GPI2(Gnd 1-4) 10 GPO2(Gnd 1-4) 10 Not used 1011 White / red GPI3(Gnd 1-4) 11 GPO3(Gnd 1-4) 11 GPO RL2COM 1112 Grey / red GPI4(Gnd 1-4) 11 GPO4(Gnd 1-4) 11 GPO RL2COM 11Not connected 12 Not connected 12 Not connected 1213 Yellow / red GPI5(Gnd 5-8) 13 GPO5(Gnd 5-8) 13 GPO RL3COM 1314 Blue / red GPI6(Gnd 5-8) 14 GPO6(Gnd 5-8) 14 Not used 1415 Orange / red GPI7(Gnd 5-8) 15 GPO7(Gnd 5-8) 15 GPO RL4COM 1516 White / black GPI8(Gnd 5-8) 15 GPO8(Gnd 5-8) 15 GPO RL4COM 15Each individual wire color can vary between manufacturing batches. Please use thecolor code that is supplied with the cable bundle.<strong>AEQ</strong> CAPITOLUltra-compact digital audio mixer35

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!