12.07.2015 Views

Buffalo Wild Wings

Buffalo Wild Wings

Buffalo Wild Wings

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Buffalo</strong> <strong>Wild</strong> <strong>Wings</strong>B. Source Limitations: Obtain EIFS from single source from single EIFS manufacturer and fromsources approved by EIFS manufacturer as compatible with system components.C. Fire Test Response Characteristics: Provide EIFS and system components with the followingfire-test-response characteristics as determined by testing identical EIFS and systemcomponents per test method indicated below by UL or another testing and inspecting agencyacceptable to authorities having jurisdiction. Identify products with appropriate markings ofapplicable testing agency.1. Surface-Burning Characteristics: Provide insulation board, adhesives, base coats, andfinish coats with flame-spread index of 25 or less and smoke-developed index of 450 orless, per ASTM E 84.2. Radiant Heat Exposure: No ignition of EIFS when tested according to NFPA 268.3. Potential Heat: Acceptable level when tested according to NFPA 259.1.08 DELIVERY, STORAGE, AND HANDLINGA. Deliver products to site in manufacturer's original, unopened containers or packaging with labelsintact clearly identifying products.B. Inspect products for damage and notify manufacturer of any discrepancies. Do not usedamaged or unsatisfactory materials.C. Store materials inside under cover protected from weather, direct sunlight, surfacecontamination, aging, damaging temperatures, construction traffic and other causes.1. Do not store at less than 40 deg. F.2. Stack insulation board flat and off the ground.1.09 PROJECT CONDITIONSA. Weather Limitations: Comply with exterior insulation finish system manufacturer’s requirementsfor temperatures and environmental conditions before during and after application.1. Do not apply EIFS system unless the ambient temperature is above 40 deg. F and rising atthe time of installation and remains so for 24 hours following installation.2. Do not apply EIFS system materials to substrates whose temperature is below 40 deg. F.3. Do not apply EIFS system during inclement weather unless appropriate protection isemployed.1.10 COORDINATIONA. Coordinate installation of EIFS with related Work specified in other Sections to ensure that wallassemblies, including sheathing, flashing, trim, joint sealants, aluminum framing systems, anddoors, are protected against damage from the effects of weather, corrosion, moisture, and othercauses. Do not allow water to penetrate behind flashing and barrier coating of EIFS.PART 2 PRODUCTS2.01 MANUFACTURERSA. Acceptable Manufacturers and System:1. Dryvit System Inc.: (Outsulation MD System).2. Senergy, Inc.: (Senerflex Channeled Adhesive System).3. STO Corporation.: (StoTherm Essence Next).4. Parex Inc.: (Standard Water Master System).2.02 MATERIALSA. Compatibility: Provide water-resistive coating, adhesive, fasteners, board insulation, reinforcingmeshes, base- and finish-coat systems, sealants, and accessories that are compatible with oneanother and with substrates and approved for use by EIFS manufacturer for Project.12/28/10 EXTERIOR INSULATION AND FINISH SYSTEM07240 -3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!