12.07.2015 Views

Buffalo Wild Wings

Buffalo Wild Wings

Buffalo Wild Wings

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Buffalo</strong> <strong>Wild</strong> <strong>Wings</strong>12. Cut aesthetic reveals in outside face of insulation with high-speed router and bit configuredto produce grooves, rabbets, and other features that comply with profiles and locationsindicated. Do not reduce insulation thickness at aesthetic reveals to less than 3/4 inch.13. Install foam shapes and attach to sheathing or structure.14. Interrupt insulation for expansion joints where indicated.15. Form joints for sealant application by leaving gaps between adjoining insulation edges andbetween insulation edges and dissimilar adjoining surfaces. Make gaps wide enough toproduce joint widths indicated on Drawings after encapsulating joint substrates with basecoat and reinforcing mesh.16. Coordinate installation of flashing and insulation to produce wall assembly that does notallow water to penetrate behind flashing and EIFS protective-coating.C. Expansion Joints: Install at locations indicated, where required by EIFS manufacturer, and asfollows:1. At expansion joints in substrates behind EIFS.2. Where EIFS adjoin dissimilar substrates, materials, and construction, including other EIFS.3. At floor lines in multilevel framed construction.4. Where wall height or building shape changes.5. Where EIFS manufacturer requires joints in long continuous elevations.3.06 BASE COAT INSTALLATIONA. Base Coat: Apply to exposed surfaces of concrete, insulation and foam shapes, as applicable,in minimum thickness recommended in writing by EIFS manufacturer, but not less than 1/16-inch dry-coat thickness.B. Reinforcing Mesh: Embed type indicated below in wet base coat to produce wrinkle-freeinstallation with mesh continuous at corners and overlapped not less than 2 inches or otherwisetreated at joints to comply with ASTM C 1397 and EIFS manufacturer's written instructions. Donot lap reinforcing mesh within 8 inches of corners. Completely embed mesh, applyingadditional base-coat material if necessary, so reinforcing-mesh color and pattern are not visible.C. Install reinforcing mesh types where recommended by the manufacturer and as follows:1. Standard Mesh: Wall areas subject to normal impact and flat walls or walls with moderatecontours.2. High Impact Mesh: Wall areas as follows:a. Areas below 8’-0” in height or subject to touch.b. Areas where projects are located in Wind Debris Zones (120 mph or higher).c. Where specifically indicated on Drawings.3. Detail Mesh: Used over special shapes and irregular detail work, at the base of a wall, ataesthetic and expansion/control joints, around openings and projections.4. Corner Mesh: For clean, crisp arises, outside corners, prefabricated panel edges andadditional impact resistance.D. Double-Layer Reinforcing Mesh Application: Where indicated, apply second base coat andsecond layer of reinforcing mesh, overlapped not less than 2 inches to comply withASTM C 1397 and EIFS manufacturer's written instructions in same manner as first application.1. Do not apply until first base coat has cured.E. Additional Reinforcing Mesh: Apply strip reinforcing mesh around openings extending 4 inchesbeyond perimeter. Apply additional 9-by-12-inch strip reinforcing mesh diagonally at corners ofopenings (re-entrant corners). Apply 8-inch- wide strip corner reinforcing mesh at both insideand outside building corners.1. At aesthetic reveals, apply strip detail reinforcing mesh not less than 8 inches wide.2. Embed strip reinforcing mesh in base coat before applying first layer of reinforcing mesh.F. Foam Shapes: Fully embed detail reinforcing mesh in base coat.12/28/10 EXTERIOR INSULATION AND FINISH SYSTEM07240 -7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!