12.07.2015 Views

Buffalo Wild Wings

Buffalo Wild Wings

Buffalo Wild Wings

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Buffalo</strong> <strong>Wild</strong> <strong>Wings</strong>2.03 FIRE EXTINGUISHER CABINETSA. (FE1 CAB): Cabinet Mounted Portable Fire Extinguishers: Type (FE1) extinguisher.B. Cabinet Configuration: Semi-recessed.1. Trim: Returned to wall surface, with 2-1/2 inch projection, 1-3/4 inch wide rolled face.2. Form cabinet enclosure with right angle inside corners and seams. Form perimeter trimand door stiles. Weld, fill, and grind components smooth.3. Metal: Formed primed steel sheet; 0.036 inch thick base metal.4. Door: 0.036 inch thick, reinforced for flatness and rigidity; latch. Hinge doors for 180degree opening with continuous piano hinge. Provide nylon catch.5. Door Glazing: Full glass, clear, 1/8 inch thick heat strengthened. Set in resilient channelgasket glazing.6. Cabinet Mounting Hardware: Appropriate to cabinet. Pre-drill for anchors.7. Finish of Cabinet Exterior Trim and Door: Manufacturer’s standard finish to accept fieldpainting under Section 09900.8. Finish of Cabinet Interior: White enamel.2.04 ACCESSORIESA. Wall Brackets: Provide metal wall brackets with strap and fasteners, of proper size for type andcapacity of extinguishers, and as required for installation conditions. Extinguisher hooks are notacceptable to hang extinguishers.PART 3 EXECUTION3.01 INSTALLATIONA. Install fire extinguishers, cabinets and mounting brackets in accordance with manufacturer’swritten instructions, in locations indicated on the drawings and in compliance with requirementsof authorities having jurisdiction.B. Cabinets: Install fire extinguisher cabinets in locations and at mounting heights indicated.1. Fasten cabinets to structure, square and plumb.2. Remove temporary protective coverings and strippable films and clean interior and exteriorsurfaces.C. Brackets: Fasten mounting brackets to structure, square and plumb. Hang fire extinguishers onbrackets and use straps to prevent free swinging.1. Mounting Height: Typically mount bracket at 48” A.F.F. If mounted unit projects greaterthan 4” out from face of wall, mount bottom of unit no greater than 27” A.F.F.3.02 SCHEDULESA. Field locate extinguishers: Maximum travel distance to extinguisher from any point in thebuilding of 75 feet.B. Check, recharge and reuse existing extinguishers that are functional. Furnish new extinguishersas required.C. Add extinguishers as required by local fire authority.END OF SECTION04-27-11 FIRE EXTINGUISHERS AND CABINETS10523 -2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!