PART 3. - EXECUTION3.1 A. The design of the sprinkler system shall be dictated by the building construction andusage and as specified herein. Piping shall be concealed above suspended ceilings.1. The design and method of installation of the fire protection work shall be inaccordance with Uniform Fire Code, UBC, International Building CodeStandards, National Fire Protection Association Standards and National FireProtection Association Standards that contain reference to or supplementarymaterial on sprinkler systems along with the requirements of the Owner’sinsurance authority, the State, and the Fire Department.2. The sprinkler systems shall be hydraulically calculated. Calculations shallconform to NFPA and UBCS 9-1.B. Coordination:1. The Contractor shall coordinate with the existing conditions, all other, buildingcomponents, all new construction, and make all necessary modifications to thepipe routing before submitting for approval. Provide hydraulic calculations for allareas of the building including supplemental hydraulic calculations for allmodification.a. Additional compensation will not be allowed for modifications to the biddocuments for additional sprinklers, coordination, or for additionalhydraulic calculations.b. Sprinkler head locations and all pipe routing shall be coordinated with allmechanical and electrical equipment and all structural and architecturalcomponents to avoid obstructions. All head locations shall becoordinated with architectural reflective ceiling plan.c. The Contractor shall carefully review all of the bid documents from alldisciplines (architectural, structural, kitchen equipment, electrical andmechanical) and design the sprinkler systems to properly protect allareas of the facility.d. The sprinkler system shall be installed in a manner that is aestheticallyunobtrusive, with all sprinkler heads symmetrically aligned and centeredin lay-in ceiling tile. System shall not interfere with existing equipmentand building components (clocks, speakers, lights, etc.), and is not to besubject to damage by the building occupants.END OF SECTION 1530006/25/09 FIRE SPRINKLER SYSTEM (PERFORMANCE BASED)15300-3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!