Technology Centre Systems Program – <strong>Draft</strong> DPR for New TC at Rohtak<br />

► The septic tanks will have adequate manholes for cleaning and maintenance purpose and will<br />

also have gas vents rising above the highest level of the buildings to avoid foul smell.<br />

► Overflow outlets of the septic tanks will be connected to secondary treatment achieved<br />

through properly designed constructed wet land system with sub-surface flow.<br />

► The constructed wetland will consist of locally available species of wetland trees, bushes and<br />

shrubs.<br />

► Collection tank of adequate capacity will be provided on the upstream of the constructed<br />

wetland to take care of incidental heavy flows.<br />

► The constructed wetland will be located suitably in the premises allowing adequate sunlight<br />

for growth of plants throughout the day.<br />

► Provision will be made to allow rejection and regeneration discharge from water treatment<br />

plant by dissolving high TDS water suitably.<br />

► Necessary de-odouring and chemical dosing will be provided at the end of wetland before the<br />

water obtained is reused.<br />

► All equipment used and the design, arrangement will be in compliance with applicable rules<br />

and regulations as laid down by town planning authority, central pollution control board and<br />

other local authorities.<br />

Ventilation system<br />

a) Internal buildings<br />

► The TC premises will have provision for sufficient ventilation. This will be done keeping in<br />

view the amount of space in the TC, number of people expected to occupy the space, type<br />

and amount of machines/equipment, and overall size of the space. The designing will be done<br />

keeping in view proper distribution of air for ventilation throughout all occupied spaces<br />

across the TC.<br />

► Natural ventilation - The premises will have adequate openings, such as doors, windows<br />

and/or vent opening to clean environment. Roof vents would be placed wherever applicable<br />

to reduce the reliance on air conditioning systems and also reduce CO2 emission in the<br />

building.<br />

► Mechanical ventilation – Mechanical parts would be installed to provide air to building<br />

occupants at a comfortable temperature and humidity that would be free of harmful<br />

concentrations of air pollutants.<br />

► Provision for adequate supply of outdoor air in the indoor environment will be provided to<br />

dilute pollutants released by equipment, building materials, furnishings, products, and<br />

people. The building’s ventilation system will be properly installed with filters to trap such<br />

particles.<br />

► Air input, smoke exhaust will also be installed and maintained for proper ventilation.<br />