Technology Centre Systems Program – <strong>Draft</strong> DPR for New TC at Rohtak<br />

SN Issues Yes/No Remarks<br />

What is the source of water<br />

9<br />

available at the site (Ground<br />

water, surface water, municipal<br />

supply, etc.)? Is the water<br />

requirement envisaged to put<br />

additional pressure on the water<br />

No<br />

The water works facility is situated adjacent to the TRTC<br />

which draws water from the treated water from canal<br />

(4-5Kms) from the facility. The treated water can be<br />

used for drinking purpose as well.<br />

sources?<br />

The TC is envisaged to have insignificant dust emissions<br />

during the construction period. Care may be exercised<br />

Will the project lead to<br />

to minimize dust emissions and its impact, if any, on the<br />

10<br />

increased air emissions in the<br />

Yes<br />

adjoining industry. Also, during the operation phase<br />

region?<br />

appropriate measures shall be undertaken to minimize<br />

air emission in case D.G set is used for electricity<br />

backup.<br />

Increase in noise level in not envisaged in the area due<br />

11<br />

Will the project lead to increase<br />

in noise levels in the area?<br />

Yes<br />

to TC. However, care like acoustic enclosures for D.G<br />

set, in case installed, construction only in day time, etc.<br />

may be practiced.<br />

The envisaged TC will only use diesel (in case D.G set is<br />

12<br />

Will the Tool room involve use of<br />

chemicals and/or solvents?<br />

No<br />

installed). However, in case any chemicals are used<br />

appropriate measures shall be undertaken to manage<br />

and store the chemicals.<br />

13<br />

Will the project involve handling,<br />

storage and disposal of<br />

hazardous waste? If yes, what<br />

are the different types of waste<br />

envisaged from the TC?<br />

No<br />

The envisaged TC will not use chemicals. However, in<br />

case, chemicals and any other hazardous materials are<br />

used measures shall be undertaken to manage the<br />

associated waste.<br />

Is the project located in the area<br />

14<br />

of seismic faults? In case yes, in<br />

which seismic does the location<br />

Yes<br />

Yes, the region has experienced history of earthquakes.<br />

The TC location falls in the Seismic zone-4.<br />

lie?<br />

Yes, the region has experienced history of earthquakes.<br />

Is there any record of natural<br />

calamity in the area in the past?<br />

Although, so far the intensity of the earthquake was not<br />

high, however, mild tremors were felt.<br />

15<br />

If yes, what is the probability of<br />

the same effecting the<br />

operations of TC in the future?<br />

Yes<br />

The probability of such incidences in future and the<br />

same effecting operations of TC is not predictable but<br />

appropriate measures shall be undertaken to ensure<br />

minimal / no damage in case of such natural calamity.<br />

Technology Centre Systems Program – DPR for New TC at Rohtak 86

Hooray! Your file is uploaded and ready to be published.