Technology Centre Systems Program – <strong>Draft</strong> DPR for New TC at Rohtak<br />

SN Issues Yes/No Remarks<br />

The selected site is defined as<br />

4<br />

industrial / commercial /<br />

Yes<br />

Industrial zone<br />

residential?<br />

Is there any protected area or<br />

biodiversity sensitive area in the<br />

There is no biodiversity sensitive or protected area in<br />

5<br />

vicinity which is likely to be<br />

No<br />

the vicinity which is likely to be affected by the<br />

affected by the operations of<br />

operations of the tool room.<br />

the tool room?<br />

6<br />

Is there any archaeological or<br />

cultural/heritage structure in<br />

the vicinity of the site?<br />

No<br />

There is no archaeological or cultural/heritage structure<br />

in the vicinity of the site.<br />

7<br />

Is there any group of indigenous<br />

people in and around the<br />

selected site?<br />

No<br />

There are no indigenous people in and around the<br />

selected site<br />

The allocated land has state highway on one of its side<br />

8<br />

Will the construction activity<br />

affect the surrounding around<br />

the tool room?<br />

Yes<br />

and Asian Paint factory on other side. As such<br />

construction and operation of the Tool Room is not<br />

envisaged to have any impact of the surrounding area.<br />

However, care may be exercised to minimize dust<br />

emissions from the construction activity.<br />

What is the source of water<br />

9<br />

available at the site (Ground<br />

water, surface water, municipal<br />

supply, etc.)? Is the water<br />

requirement envisaged to put<br />

additional pressure on the water<br />

No<br />

The water works facility is situated adjacent to the TRTC<br />

which draws water from the treated water from canal<br />

(4-5Kms) from the facility. The treated water can be<br />

used for drinking purpose as well.<br />

sources?<br />

The TC is envisaged to have insignificant dust emissions<br />

during the construction period. Care may be exercised<br />

Will the project lead to<br />

to minimize dust emissions and its impact, if any, on the<br />

10<br />

increased air emissions in the<br />

Yes<br />

adjoining industry. Also, during the operation phase<br />

region?<br />

appropriate measures shall be undertaken to minimize<br />

air emission in case D.G set is used for electricity<br />

backup.<br />

Increase in noise level in not envisaged in the area due<br />

11<br />

Will the project lead to increase<br />

in noise levels in the area?<br />

Yes<br />

to TC. However, care like acoustic enclosures for D.G<br />

set, in case installed, construction only in day time, etc.<br />

may be practiced.<br />