source VLANs :<br />

rx :<br />

destination ports : Eth1/5 (f+l)<br />

Legend: f = forwarding enabled, l = learning enabled<br />

source VSANs :<br />

rx : rx :<br />

Configuration of Fibre Channel SPAN is similar to a typical Ethernet SPAN configuration.<br />

If the destination port is a Fibre Channel interface, it must be configured as a SPAN<br />

Destination (SD) port under the interface configuration, as demonstrated in Example 7-13.<br />

Example 7-13. Configuring a SPAN Session with a Fibre Channel Destination Port<br />

Click here to view code image<br />

CMHLAB-N5K1# config t<br />

Enter configuration comm<strong>and</strong>s, one per line. End with<br />

CNTL/Z.<br />

CMHLAB-N5K1(config)# int fc2/3<br />

CMHLAB-N5K1(config-if)# switchport speed 2000<br />

CMHLAB-N5K1(config-if)# switchport mode sd<br />

CMHLAB-N5K1(config-if)# no shut<br />

CMHLAB-N5K1(config)# monitor session 2<br />

CMHLAB-N5K1(config-monitor)# desc SPAN Session for Fibre<br />

Channel<br />

CMHLAB-N5K1(config-monitor)# source interface vfc10<br />

CMHLAB-N5K1(config-monitor)# destination int fc2/3<br />

CMHLAB-N5K1(config-monitor)# no shut<br />

CMHLAB-N5K1(config-monitor)# end<br />

CMHLAB-N5K1#<br />

The session’s configuration can be verified by using the show monitor session comm<strong>and</strong>, as<br />

demonstrated in Example 7-14.<br />

Example 7-14. Displaying a Fibre Channel Monitor Session<br />

Click here to view code image<br />

CMHLAB-N5K1# show mon sess 2<br />

session 2<br />

---------------<br />

description : SPAN Session for Fibre Channel<br />

type<br />

: local