interface vfc101<br />

bind interface ethernet-port-channel258<br />

switchport mode E<br />

switchport trunk allowed vsan 2000<br />

no shutdown<br />

MDS9506-1# MDS9506-1# show int vfc101<br />

vfc101 is trunking<br />

Bound interface is ethernet-port-channel258<br />

Hardware is Ethernet<br />

Port WWN is 20:64:00:0d:ec:35:1e:ff<br />

Admin port mode is E, trunk mode is on<br />

snmp link state traps are enabled<br />

Port mode is TE<br />

Port vsan is 1<br />

Speed is 40 Gbps<br />

Trunk vsans (admin allowed <strong>and</strong> active) (2000)<br />

Trunk vsans (up) (2000)<br />

Trunk vsans (isolated) ()<br />

Trunk vsans (initializing) ()<br />

117696 fcoe in packets<br />

10091312 fcoe in octets<br />

117695 fcoe out packets<br />

13575440 fcoe out octets<br />

Interface last changed at Tue Jul 31 01:17:09 2012<br />

MDS9506-1#<br />

FCoE on the Nexus 7000 also supports a unique capability that enables interfaces to be<br />

shared between two VDCs. This enables the Nexus 7000 to be used in the access layer of<br />

networks where servers connect to the switch <strong>and</strong> use FCoE. A shared interface enables<br />

FCoE traffic to be segmented into the Storage VDC at the edge of the network. When an<br />

interface is shared between two VDCs, a few rules must be followed:<br />

• Interfaces can be shared only between one Ethernet VDC <strong>and</strong> one Storage VDC.<br />

• Interfaces to be shared must be configured as 802.1Q trunks in the Ethernet VDC.<br />

• Interfaces may be shared only from the Ethernet VDC that allocated VLANs to the<br />

Storage VDC.<br />

• The Ethernet VDC “owns” the physical interface. If the interface is admin down in the<br />

Ethernet VDC, it will be admin down in the Storage VDC.<br />

• All ports that have a common ASIC must be allocated as shared interfaces. This is<br />

done in groups of two on the F1 modules <strong>and</strong> groups of four on F2/F2e modules.