Parameter to<br />

bedetermined, unit<br />

of measurement<br />

Density at 20º,<br />

kg/m³<br />

Kinematic viscosity<br />

at 50º, mm²/s<br />

Kinematic viscosity<br />

at 20º, mm²/s<br />

Closed flash point,<br />

º<br />

Chill point, º<br />

Acid number, mg<br />

KOH per 1 g of oil<br />

Standard for<br />

Sulphuric-acid<br />

refining<br />

condenser oil<br />

according to<br />

GOST 5775-85<br />

Tables 6.1.16 Study of composition and properties of oil products<br />

collected at site * 164, 330<br />

Actual values of paramaters based on testing results<br />

L05-03-6 L05-03-7 L05-03-8 L05-04-9<br />

- 877.3 873.9 873.8 884.8<br />

not more than<br />

12.0<br />

not more than<br />

45.0<br />

not lower than<br />

135<br />

not higher<br />

than -14<br />

not more than<br />

0.02<br />

11.77 10.57 10.51 10.51<br />

33.76 29.25 29.03 29.03<br />

153 145 141 147<br />

-48.8 -53.3 -53.9 < -56.6<br />

0.057 0.008 0.015 0.055<br />

Ash content, % absent absent absent absent absent<br />

Content water<br />

soluble acids and<br />

alkalies<br />

Conclusion<br />

Type of oil product<br />

according to GOST<br />

absent absent absent absent absent<br />

The results of laboratory study of physico-chemical characteristics show that<br />

specimens L05-03-6, L05-03-7, L05-03-8, L05-04-9 is sulphuric-acid refining<br />

condenser oil. As for such parameters as kinematic viscosity at 50º and 20º, closed<br />

flash point, chill point, ash content and content water soluble acids and alkalies, all<br />

specimens meet the requirements of GOST 5775-85. parameter acid number in<br />

specimens L05-03-7 and L05-03-8 meet GOST requirements, in specimens L05-03-6<br />

and L05-04-9 this parameter is higher by 2.85 and 2.75 times respectively.<br />

Sulphuric-acid<br />

refining<br />

condenser oil<br />

Sulphuric-acid<br />

refining<br />

condenser oil<br />

Sulphuric-acid<br />

refining<br />

condenser oil<br />

* 164-Destroyed building-transformer and condenser storage facility, 330-Transformer and condenser dump<br />

Sulphuric-acid<br />

refining<br />

condenser oil<br />

In the area of radar station 2 specimens were identified as transmission oils of viscosity class 18 and<br />

8 specimens as sulphuric-acid refining condenser oil according to GOST 5775-85<br />

FINAL REPORT for Contract No. CS-NPA-Arctic-13/2009 of December 01, 2009 within the framework of pilot project Development of<br />

Technology of clean up of the area of Decommissioned Sites of The Russian Federation Ministry of Defense in the Arctic by the<br />

Example of Alexanra Island of Franz Josef Land Archipelago from Hazardous Waste<br />

131

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!