Getting Started<br />
Assign the 'NO_Contactor' to the 'Emergency Off' coil. After the contact has been assigned,<br />
the cross-reference is applied online to the contact and the contact comb after clicking the left<br />
mouse button anywhere in the drawing field. Exit the Symbol Explorer with 'Cancel'.<br />
Hint<br />
This procedure can also be reversed. This means that a contact can be<br />
loaded first and a part number (from the database) can be assigned. As the<br />
part is assigned, the automatic process identifies and manages the contact<br />
arrangement even when the coil is not yet positioned on the drawing<br />
sheet.<br />
Cross-reference Navigator<br />
Now you can learn how to access the position a cross-reference is pointed to,<br />
quickly and easily.<br />
Let's use the contact comb of the contactor 'Feed forward' as an example. Note<br />
the cross-reference text at the left of the comb; this represents the position of the<br />
associated contact.<br />