Chapter 3: General System Tasks<br />

Configuring the <strong>Sidewinder</strong> <strong>G2</strong> to use a UPS<br />

94<br />

Figure 42: UPS<br />

Configuration window<br />

About the UPS<br />

Configuration<br />

window<br />

The UPS Configuration window enables you to configure how the <strong>Sidewinder</strong><br />

<strong>G2</strong> will interact with an uninterruptible power supply. The window contains the<br />

following fields.<br />

• UPS Serial Port—Click the drop-down list to select the <strong>Sidewinder</strong> <strong>G2</strong> port<br />

being used to monitor the UPS.<br />

The <strong>Sidewinder</strong> <strong>G2</strong> only supports COM1 port (COM2 is not supported).<br />

Therefore, you cannot enable the uninterruptible power supply (UPS) service<br />

AND connect a console directly on your <strong>Sidewinder</strong> <strong>G2</strong> on the COM1<br />

port at the same time. Doing so will cause your <strong>Sidewinder</strong> <strong>G2</strong> Security<br />

Appliance to shutdown immediately. If this happens, you must do one <strong>of</strong> the<br />

following:<br />

– Disable upsd and use a serial console: Disconnect the <strong>Sidewinder</strong> <strong>G2</strong><br />

console, disable upsd using the Admin Console, and then reconnect to<br />

the <strong>Sidewinder</strong> <strong>G2</strong> console.<br />

– Remove the serial console and use upsd: Disconnect the <strong>Sidewinder</strong><br />

<strong>G2</strong> console, and then connect the UPS cable.<br />

• Battery Time—Specify the estimated amount <strong>of</strong> time (in seconds) that the<br />

UPS battery will last before running low. The <strong>Sidewinder</strong> <strong>G2</strong> will initiate an<br />

orderly shutdown when this timer expires, regardless <strong>of</strong> the amount <strong>of</strong><br />

battery power remaining in the UPS.