Adjustments<br />

This <strong>ch</strong>apter documents the adjustments for the <strong>HP</strong> <strong>8648</strong> and the<br />

service support software that is used for the automated adjustments.<br />

There are both manual and automated adjustment procedures<br />

documented in this <strong>ch</strong>apter. This <strong>ch</strong>apter is organized with the<br />

following order:<br />

Manual adjustments procedures<br />

Automated adjustment descriptions<br />

w Service support software description<br />

Refer to ‘lable 5-2 for information regarding whi<strong>ch</strong> adjustments should<br />

be performed after an assembly is repaired or replaced.<br />

Test Equipment The required test equipment for the adjustments is listed in ‘Ruble 5-l.<br />

Along with the required test equipment, this table lists the critical<br />

specifications of ea<strong>ch</strong>, the recommended model number, and the<br />

adjustments that this equipment is used to perform.<br />

Equipment Setup for The complete test equipment setup includes the <strong>HP</strong> <strong>8648</strong> that is being<br />

Automated Tests tested (the DUT), a personal computer (PC) that runs the adjustment<br />

software, and the various instruments that make up the electronic<br />

test equipment. The PC must have a Hewlett-Packard Interface Bus<br />

(<strong>HP</strong>-IB) installed in one of its card slots. The DUT is connected to<br />

the PCs <strong>HP</strong>-IB card via a Hewlett-Packard Interface Bus (<strong>HP</strong>-IB)<br />

cable. Another <strong>HP</strong>-IB cable connects the PC to the electronic test<br />

equipment. The electronic test equipment must be connected together<br />

via additional <strong>HP</strong>-IB cables.<br />

Note Although the test setup illustrations do not show the PC or the <strong>HP</strong>-IB<br />

cable connections, these connections are required to perform the<br />

automated tests and adjustments.<br />