Signaling Examples<br />

Function<br />

The following examples illustrate the frame structure for the three<br />

transmission repetition settings. The HEADER and TERMINATOR<br />

parameters are set to ON (default), and the COLLAPSE CYCLE (CC) is<br />

set to 1 and 2 (messages will be repeated every 2 frames (2l) and<br />

4 frames (22) respectively).<br />

SINGLE Mode Example<br />

Start Cycle: 10<br />

Start Frame: 127<br />

Collapse Cycle: Has no effect<br />

Since HEADER is set to ON, the idle signal is output at Frame 126.<br />

With TERMINATOR set to ON, the asyn<strong>ch</strong>ronous state signal is<br />

output after the message.<br />

BURST Mode Example<br />

FCC= 1 idle message asyn<strong>ch</strong>ronous<br />

ICC=2 Iidle)messageIasyn<strong>ch</strong>ronousI<br />

Start Cycle: 10<br />

Start Frame: 127<br />

Collapse Cycle: 1 (2l) and 2 (22)<br />

Burst: 3<br />

Since HEADER is set to ON, the idle signal is output at Frame 126.<br />

With TERMINATOR set to ON, the asyn<strong>ch</strong>ronous state signal is<br />

output in the frame where the next message was supposed to<br />

occur (as determined by the collapse cycle).<br />

H-t<br />

Cycle 10<br />

Frame 126<br />

10<br />

127<br />

11<br />

0<br />

11<br />

1<br />

11<br />

2<br />

11<br />

3<br />

11<br />

4<br />

11<br />

5<br />

11<br />

6<br />

11<br />

7<br />

11<br />

11<br />

CC= 1 idle message idle message idle message idle asyn<strong>ch</strong>ronous<br />

CC=2 idle message idle idle idle message idle idle idle message asyn<strong>ch</strong>ronous<br />

Operation Reference 1 b-23