Pulse Modulation<br />

Rise Time<br />

Performance Tkst<br />

(Option lE6 Only)<br />

Connect the Test<br />

Equipment<br />

Configure the Pulse<br />

Generator<br />

Configure the <strong>HP</strong> <strong>8648</strong><br />

Configure the<br />

Oscilloscope<br />

Measure the Rise Time<br />

Pulse Modulation Rise Time Performance Test (Option lE6 Only)<br />

gssssssB E<br />

8~088888 B<br />

DIGITIZING<br />

OSCILLOSCOPE<br />

5”7 IbC<br />

Figure 8-19. Pulse Modulation On/Off Risetime Equipment Setup.<br />

1. Mode normal<br />

2. Frequency 10 MHz<br />

3. Duty cycle 50%<br />

4. Amplitude 1 V<br />

5. Offset 1 V<br />

1. Turn the RF output on; press [RF).<br />

2. Activate pulse modulation display; press (EGJ (AM).<br />

3. Turn pulse modulation on; press [MOD ON/OFF].<br />

4. Set the amplitude; press m @ @kGYj’J.<br />

1. Channel 1 125 mV/div<br />

2. Trigger source <strong>ch</strong>annel 4<br />

3. Trigger level 1.5 V<br />

4. Timebase 10 ns/div<br />

1. Use the timebase delay to align a rising pulse edge with the center<br />

of the oscilloscope screen.<br />

2. Change the timebase to 2 ns/div.<br />

3. Display the envelope of <strong>ch</strong>annel 1.<br />

4. Set the frequency of the <strong>HP</strong> <strong>8648</strong> to that listed in the test record.<br />

For this frequency measure the 10% to 90% rise time of the RF<br />

pulse.<br />