3 Select entries in the Marker 1 and Marker 2 lists. Click OK.<br />

Intervals generate with a start time that corresponds to the occurrence times<br />

of the Marker 1 selection. The end time correspond to the first subsequent<br />

occurrence time of the Marker 2 selection. <strong>CinePlex</strong> Editor ignores additional<br />

occurrences of Marker 1 that occur before an ending Marker 2.<br />

4 Select entries in the Marker 1 list. In the two Time Offset... boxes, enter time<br />

offsets TS and TE in seconds. Click OK.<br />

Note:<br />

For every occurrence of Marker 1 at time t, an interval generates from<br />

time t + TS to time t + TE, where TS and TE are the time offsets<br />

entered in the first and second marker boxes respectively. TS and TE<br />

can be positive or negative.<br />

5 Select entries in the Marker 1 and Marker 2 lists, and enter time offsets in the<br />

Time Offset... boxes. Offsets can be positive or negative. Click OK.<br />

Note:<br />

This is a generalization of the first algorithm where the interval is offset<br />

in a fashion similar to the second algorithm from the exact times of<br />

the start and end marker occurrences.<br />

6 In the Ranges File box, type or select a text file that contains the ranges.<br />

Click OK.<br />

Note:<br />

The format of the text file is one range per line of text, with each line<br />

containing the start time and end time in seconds. The delimiter<br />

between the times can be a comma, a space, or a tab.<br />

Automatically generating Scalar and Coordinate marker occurrences<br />

• In the Define New Marker dialog box, if the user selects S (Scalar) or C<br />

(Coordinate) and clicks Generate Occurrences, <strong>CinePlex</strong> Editor just generates<br />

some fake, random data for testing and demonstration purposes. It has<br />

no usefulness in general.<br />

Automatically generating Level Interval and Zone Interval marker<br />

occurrences<br />

• In the Define New Marker dialog box, if the user selects L (Level Interval) or<br />

R (Zone Interval) and clicks Generate Occurrences, <strong>CinePlex</strong> Editor<br />

defines the new marker and then opens either the Levels Editor or Zones<br />

Editor dialog boxes. Use the editors to generate occurrences based on level<br />

crossings for Scalar markers, or Zone containment for Coordinate markers.<br />

For basic information, see “Using the Levels Editor” on page 185 and<br />

“Using the Zones Editor” on page 188. For detailed information on each<br />

editor, see “Levels Editor” on page 254 and “Zones Editor” on<br />

page 256.<br />

4.5.5 Using the Levels Editor<br />

The user may use the Levels Editor to define Level Interval markers and insert<br />

marker occurrences for them. To open the Levels Editor dialog box, from the<br />

Version 3.0 185