Derricks and Portable Masts 507<br />

The manufacturer shall establish the reduced rated static hook loads for the<br />

same conditions under which the maximum rated static hook loads apply, but<br />

with the addition of the pipe-setback and sucker-rod loadings. The reduced rated<br />

static hook loads shall be expressed as percentages of the maximum rated static<br />

hook loads. Thus, the portable mast ratings in Standard 4D include a safety<br />

factor of 2 to allow for wind and impact loads, and require the manufacturer<br />

to specify further capacity reductions due to setback.<br />

The policy of Standard 4D, that the manufacturer specify the structure load<br />

capacity for various loading configurations, has been applied in detail in<br />

Standards 4E (superseded by Standard 4F) and 4F. Standard 4F calls for detailed<br />

capacity ratings that allow the user to look up the rating for a specific loading<br />

configuration. These required ratings are as follows.<br />

Standard Ratings<br />

Each structure shall be rated for the following applicable loading conditions.<br />

The structures shall be designed to meet or exceed these conditions in<br />

accordance with the applicable specifications set forth herein. The following<br />

ratings do not include any allowance for impact. Acceleration, impact, setback,<br />

and wind loads will reduce the rated static hook load capacity.<br />

Derrlck-Stationary<br />

Base<br />

1. Maximum rated static hook load for a specified number of lines to the<br />

traveling block.<br />

2. Maximum rated wind velocity (knots) without pipe setback.<br />

3. Maximum rated wind velocity (knots) with full pipe setback.<br />

4. Maximum number of stands and size of pipe in full setback.<br />

5. Maximum rated gin pole capacity.<br />

6. Rated static hook load for wind velocities varying from zero to maximum<br />

rated wind velocity with full rated setback and with maximum number of<br />

lines to the traveling block.<br />

Mast with Guy Lines<br />

1. Maximum rated static hook load capacity for a specified number of lines<br />

strung to the traveling block and the manufacturer’s specified guying.<br />

2. Maximum rated wind velocity (knots) without pipe setback.<br />

3. Maximum rated wind velocity (knots) with full pipe setback.<br />

4. Maximum number of stands and size of pipe in full setback.<br />

Mast wlthout Guy Lines<br />

traveling block.<br />

1. Maximum rated static hook load for a specified number of lines to the<br />

2. Maximum rated wind velocity (knots) without pipe setback.<br />

3. Maximum rated wind velocity (knots) with full pipe setback.<br />

4. Maximum number of stands and size of pipe in full setback.<br />

5. Rated static hook load for wind velocities varying from zero to maximum<br />

rated wind velocity with full rated setback and with maximum number of<br />

lines to the traveling block.