564 Drilling and Well Completions<br />

Table 4-11<br />

Weiaht of Zinc Coatina for Galvanized Row Wire 1121<br />

(1) (2) (3) (4)<br />

Minimum Weight<br />

DiamterOfWirt<br />

of Zinc Coating<br />

in. mm dft2 ktw<br />

0.028 to 0.047 0.71 to 1.19 0.20 0.06<br />

0.048 to 0.054 1.22 to 1.37 0.40 0.12<br />

0.055 to 0.063 1.4oto 1.60 0.50 0.15<br />

0.064 to 0.079 1.63 to 201 0.60 0.18<br />

0.080 to 0.092 203 to 2.34 0.70 0.21<br />

0.093 and larga 2.36 and 1- 0.80 0.24<br />

Table 4-12<br />

Weight of Zinc Coating for<br />

Drawn-Galvanized Rope Wire [12]<br />

(1) (2) (3) (4)<br />

Diameter of wm<br />

Minimum Weight<br />

of zinc coaling<br />

in. mm ozJft2 kl@<br />

0.018 to 0.028 0.46 to 0.71 0.10 0.03<br />

0.029 to 0.060 0.74 to 1.52 0.20 0.06<br />

0.061 to 0.090 1.55 to 2.29 0.30 0.09<br />

0.091 too.140 2.31 to 3.56 0.40 0.12<br />

wire rope; such sample must be new or in an unused condition. The total wire<br />

number to be tested shall be equal to the number of wires in any one strand,<br />

and the wires shall be selected from all strands of the rope. The specimens shall<br />

be selected from all locations or positions so that they would constitute a<br />

compIete composite strand exactly similar to a regular strand in the rope. The<br />

specimen for all "like-positioned" (wires symmetrically placed in a strand) wires<br />

to be selected so as to use as nearly as possible an equal number from each strand.<br />

Any unsymmetrically placed wires, or marker wires, are to be disregarded<br />

entirely. Center wires are subject to the same stipulations that apply to symmetrical<br />

wires.<br />

Selection and testing of wire prior to rope fabrication will be adequate to ensure<br />

the after-fabrication wire rope breaking strength and wire requirements can be met.<br />

Prior to fabrication, wire tests should meet the requirements of Table 410.<br />

Conduct of Tests. The test results of each test on any one specimen should<br />

be associated and may be studied separately from other specimens.<br />

If, when making any individual wire test on any wire, the first specimen fails,<br />

not more than two additional specimens from the same wire shall be tested.<br />

The average of any two tests showing failure or acceptance shall be used as the<br />

value to represent the wire. The test for the rope may be terminated at any time<br />

sufficient failures have occurred to be the cause for rejection.