28.11.2014 Views

article 5. zoning district regulations - City of Wilmington

article 5. zoning district regulations - City of Wilmington

article 5. zoning district regulations - City of Wilmington

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Land Development Code<br />

<strong>City</strong> <strong>of</strong> <strong>Wilmington</strong><br />

parking in the interior side or rear yard <strong>of</strong> the sites. No <strong>of</strong>f-street parking shall be<br />

located in the front or corner side yard <strong>of</strong> the site.<br />

(6) Front setback <strong>of</strong> proposed new construction--All new nonresidential or<br />

multifamily structures in the Wrightsville Avenue Corridor Overlay shall be setback a<br />

minimum <strong>of</strong> twenty (20) feet from the Wrightsville Avenue street right-<strong>of</strong>-way. In<br />

those instances in which adjoining properties have a setback less than the specified<br />

twenty (20) feet, new nonresidential construction may be placed in alignment with the<br />

average setback <strong>of</strong> existing structures along the block face in which the new structure<br />

is located.<br />

(7) Building height--All new nonresidential or multifamily structures in the<br />

Wrightsville Avenue Corridor Overlay shall be built to a height no greater than two<br />

(2) stories or twenty-five (25) feet in height, whichever is greater.<br />

(8) Site lighting--All new nonresidential or multifamily developments in the<br />

Wrightsville Avenue Corridor Overlay shall be restricted to site lighting <strong>of</strong> the<br />

following height:<br />

a. Unrestricted lighting--Ten (10) feet.<br />

b. Ninety (90) degree cut<strong>of</strong>f lighting--Fifteen (15) feet.<br />

(9) Signage--All nonresidential property in the Wrightsville Avenue Corridor<br />

Overlay shall be subject to the sign size and setback standards for the Office and<br />

Institutional District with regard to freestanding signs. In addition, freestanding signs<br />

shall be a maximum height <strong>of</strong> twelve (12) feet. No internally illuminated freestanding<br />

signs shall be permitted. Existing signage shall be subject to amortization within eight<br />

(8) years <strong>of</strong> adoption <strong>of</strong> this Corridor Overlay.<br />

(10) Streetscape Architectural Components--All new nonresidential or multifamily<br />

structures in the Wrightsville Avenue Corridor shall contain door and window<br />

openings consistent with those found in the adjacent streetscape. Blank facades shall<br />

not be permitted on the Wrightsville Avenue frontage <strong>of</strong> the structure.<br />

(b) For all conversions or additions to existing structures for nonresidential or<br />

multiple family uses, the following design standards shall apply:<br />

(1) The construction <strong>of</strong> an addition to existing structures in the corridor shall be<br />

placed in the rear <strong>of</strong> the structure where site dimensions and orientation permit. The<br />

size and scale <strong>of</strong> the addition shall be limited in size so that the addition shall contain<br />

no more than fifty (50) percent <strong>of</strong> the square footage <strong>of</strong> the original building.<br />

(2) The attached addition shall be designed in a manner that is compatible with the<br />

new use to which the structure will be placed, and shall also be designed for<br />

compatibility with the structure itself, and with buildings in the adjacent<br />

neighborhood or immediate streetscape. The design may be contemporary in nature,<br />

but should reference design features from the original structure including building<br />

materials, building openings and height. The addition shall not be constructed <strong>of</strong><br />

materials not found in the existing streetscape, shall not feature blank facades, and<br />

shall not be out <strong>of</strong> scale with the original building.<br />

(3) The urban design standards for new construction (see Sec. 18-213. CO, Corridor<br />

Overlay Districts. shall be observed for building scale, <strong>of</strong>f-street parking, front<br />

setback, building height, site lighting and signage.<br />

ARTICLE <strong>5.</strong> ZONING DISTRICT REGULATIONS Page 118

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!