01.12.2014 Views

Directive 065: Resources Applications for Oil and Gas Reservoirs ...

Directive 065: Resources Applications for Oil and Gas Reservoirs ...

Directive 065: Resources Applications for Oil and Gas Reservoirs ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

7.4.6 ERCB Spacing Application Decision Tree<br />

Figure 7.7 outlines the ERCB decision process <strong>for</strong> holding applications.<br />

Question 1<br />

Does your area of application include entire DSUs?<br />

Yes<br />

Question 2<br />

Does each applied-<strong>for</strong> holding have common ownership at the lessor <strong>and</strong><br />

lessee level?<br />

No<br />

The<br />

application<br />

cannot be<br />

filed.<br />

Yes<br />

Question 3<br />

Question 5<br />

Is each applied-<strong>for</strong> holding/unit<br />

adjacent to a previously approved<br />

area <strong>for</strong> the same <strong>for</strong>mation(s)/<br />

pool(s)?<br />

Yes<br />

Question 4<br />

Does every DSU in each applied<strong>for</strong><br />

holding/unit have an adjacent<br />

DSU with approved spacing <strong>and</strong><br />

production data?<br />

No<br />

No<br />

Is any part of each applied-<strong>for</strong><br />

holding/unit within 3 st<strong>and</strong>ard<br />

DSUs of a previously approved<br />

area <strong>for</strong> the same <strong>for</strong>mation(s)/<br />

pool(s)?<br />

Yes<br />

Question 7<br />

Does each proposed holding/unit<br />

contain production data in the<br />

applied-<strong>for</strong> <strong>for</strong>mation(s)/pool(s)?<br />

No<br />

No<br />

Limited data<br />

may mean the<br />

application is<br />

premature.<br />

Yes<br />

Yes<br />

Question 6<br />

Is the proposed well density less than or equal to the well density in the<br />

previously approved area?<br />

No<br />

Yes<br />

Question 9<br />

Yes<br />

Is the proposed well density less than or equal to 4 wells per pool per section<br />

(gas) or 2 wells per pool per quarter section (oil)?<br />

No<br />

Question 8<br />

Is the density of the oil 920 kg/m 3<br />

or greater @ 15 C?<br />

Yes<br />

No<br />

Yes<br />

Question 10<br />

Yes<br />

Yes<br />

Question 9<br />

Is the proposed well density less<br />

than or equal to 4 wells per pool<br />

per quarter section?<br />

No<br />

Is the applied-<strong>for</strong> buffer zone equal to the st<strong>and</strong>ard buffer zone <strong>for</strong> the area<br />

of application <strong>and</strong> production source as specified in <strong>Directive</strong> <strong>065</strong>?<br />

No<br />

Yes<br />

Application may be<br />

Quick<br />

Yes<br />

Application may be<br />

St<strong>and</strong>ard<br />

Application is<br />

Nonst<strong>and</strong>ard<br />

St<strong>and</strong>ard buffering <strong>for</strong> oil<br />

100 m on all boundaries of the holding(s).<br />

St<strong>and</strong>ard buffering <strong>for</strong> gas<br />

Outside 13A: 150 m on all boundaries of the holding(s).<br />

13A: 150 m on the south <strong>and</strong> west boundaries of the holding(s).<br />

Figure 7.7. ERCB decision tree <strong>for</strong> holding/unit applications<br />

ERCB <strong>Directive</strong> <strong>065</strong>: <strong>Resources</strong> <strong>Applications</strong> / Application <strong>for</strong> Special Well Spacing (October 2011) • 7-17