Figure 3.4. Decision Tree to Determine If the Proposed Commingling Is a C<strong>and</strong>idate <strong>for</strong><br />
Self-Declared <strong>Oil</strong> Commingling in a Well<br />
1. If there are any per<strong>for</strong>ations above the base of groundwater protection, is it anticipated that<br />
there would be water production equal to or greater than 5 m 3 /well/month from all the intervals<br />
in the well? See Explanatory Note 3.<br />
YES<br />
NO<br />
2. Are there any water wells within a 600 m radius with a total depth less than 25 m from the<br />
top of the per<strong>for</strong>ations of the well proposed <strong>for</strong> commingling? See Explanatory Note 4.<br />
NO<br />
3. Does the proposed commingled production stream contain any H 2 S?<br />
See Explanatory Note 5.<br />
NO<br />
4. Does the reservoir pressure in any of the pools or intervals proposed <strong>for</strong> commingling<br />
exceed 90% of the lesser of the closure or breakdown fracture pressure of any of the other<br />
pools or intervals proposed <strong>for</strong> commingling (pressure adjusted <strong>for</strong> gas <strong>and</strong> liquid gradients if<br />
necessary)? See Explanatory Note 7.<br />
NO<br />
5. Are there any unresolved equity issues with respect to the intervals proposed <strong>for</strong><br />
commingling? See Explanatory Note 8.<br />
NO<br />
6. Is the well in a designated oil s<strong>and</strong>s area or in a pool that overlaps a designated oil s<strong>and</strong>s<br />
area? See Explanatory Note 9.<br />
NO<br />
7. Are any of the pools or intervals proposed <strong>for</strong> commingling subject to any existing or<br />
proposed enhanced recovery schemes? See Explanatory Note 10.<br />
YES<br />
YES<br />
YES<br />
YES<br />
YES<br />
YES<br />
NO<br />
8. Does the proposed commingling mix oil <strong>and</strong> nonassociated gas? See Explanatory Note 11.<br />
YES<br />
NO<br />
9. Do the oil pools proposed <strong>for</strong> commingling have different rate administration? See<br />
Explanatory Note 12.<br />
YES<br />
NO<br />
10. Do any of the oil pools proposed <strong>for</strong> commingling have associated gas caps that have not<br />
been approved <strong>for</strong> concurrent production? See Explanatory Note 13.<br />
YES<br />
NO<br />
11. Do any of the pools proposed <strong>for</strong> commingling (any combination of new completions <strong>and</strong><br />
existing producing completions) have wells capable of producing a commingled flow rate<br />
greater than 3 m 3 /d? See Explanatory Note 14.<br />
YES<br />
NO<br />
Commingling from the intervals may proceed without any ERCB approval.<br />
Notice of commingling must be given to Freehold owners <strong>and</strong> well licensees, as indicated in<br />
Explanatory Note 8.<br />
Production must be reported through the Petroleum Registry of Alberta using the appropriate<br />
SD code.<br />
File an application in<br />
accordance with<br />
Section 3.1.8 of<br />
<strong>Directive</strong> <strong>065</strong>.<br />
Data requirements in accordance with Sections 11.005, 11.040, 11.070, 11.102, 11.140, <strong>and</strong><br />
11.145 of the OGCR <strong>and</strong> <strong>Directive</strong> 040 must be met <strong>and</strong> are subject to audit.<br />
ERCB <strong>Directive</strong> <strong>065</strong>: <strong>Resources</strong> <strong>Applications</strong> / Commingled Production (October 2011) • 3-13