01.12.2014 Views

Directive 065: Resources Applications for Oil and Gas Reservoirs ...

Directive 065: Resources Applications for Oil and Gas Reservoirs ...

Directive 065: Resources Applications for Oil and Gas Reservoirs ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

• <strong>Resources</strong> <strong>Applications</strong> Schedule 1<br />

• ER Scheme application <strong>for</strong>m (Appendix F),<br />

• Attachments<br />

- Application<br />

- Approval Area Map<br />

- Pressure-Volume-Temperature (PVT) Data<br />

- Reserves Data<br />

- Licensee Concerns (if there are any unresolved concerns)<br />

- Isopach Map (<strong>for</strong> new ER schemes <strong>and</strong> significant area amendments)<br />

- Well Log(s) (<strong>for</strong> new ER schemes <strong>and</strong> significant area amendments)<br />

- Pressure Data <strong>and</strong> Interpretation (<strong>for</strong> new ER schemes <strong>and</strong> significant area<br />

amendments)<br />

- Structure Map (<strong>for</strong> new gas cycling schemes)<br />

- Miscellaneous (additional in<strong>for</strong>mation to support the request)<br />

Further explanation on the ER Scheme application <strong>for</strong>m <strong>and</strong> attachments is provided in the<br />

following sections (B) <strong>and</strong> (C).<br />

B) Explanatory Notes <strong>for</strong> ER Scheme Application Form Questions<br />

The ER Scheme application <strong>for</strong>m is in Appendix F. The numbering below corresponds to the<br />

questions on the <strong>for</strong>m.<br />

Application Type<br />

1) Type of ER scheme being proposed or amended:<br />

Only one type of ER scheme may be selected. Although schemes may have multiple types of<br />

injection fluid, there generally is a predominant recovery mechanism or scheme type. For<br />

example, a scheme with water-alternating-gas (WAG) injection is a miscible scheme even<br />

though solvent, water, <strong>and</strong> gas would be injected during the scheme’s life.<br />

If you choose Other, you must include a description of the ER process <strong>and</strong> supporting<br />

technical documents/papers discussing the method in the application.<br />

2) Is this application <strong>for</strong> a new ER scheme or an amendment to an existing ER scheme<br />

approval?<br />

If an ERCB approval <strong>for</strong> ER does not exist <strong>for</strong> the subject scheme, select New.<br />

If an ERCB approval <strong>for</strong> ER exists <strong>for</strong> the subject scheme, select Amendment.<br />

2-8 • ERCB <strong>Directive</strong> <strong>065</strong>: <strong>Resources</strong> <strong>Applications</strong> / Enhanced Recovery Scheme (October 2011)