<strong>F4200N</strong> Operating <strong>Manual</strong><br />

Section 5: Point Type & Function Reference<br />

Part # 562187N<br />

Rev. C Jun 2011<br />

1.3 Line Passing<br />

Registers the current XYZ location as a Line Passing point. This is a location on the line<br />

where the tip changes direction, such as at the corner on a rectangle.<br />

Also use a Line passing point before and after an Arc Point instruction.<br />

1.4 Circle<br />

Registers a circle, where the circle‟s center is at the current XYZ location. To register a<br />

circle, jog the tip to the circle‟s center and press ENTER, and then press the key 4 (for<br />

circle). The display will prompt you to type the following data:<br />

Diameter: Type the diameter of the circle and press ENTER.<br />

Over Angle: (The value is <strong>fr</strong>om 1~360). After dispensing the circle, while going through an<br />

extra part of the circle defined by the Over Angle, the dispenser will be<br />

turned OFF.<br />

Z Lift: 1. Yes 2. No<br />

Selection:<br />

If you want the Z-axis (tip) to lift while going through the Over Angle, you<br />

must select 1. Otherwise: select 2.<br />

The speed must be set in a previous memory address by registering a Line Speed<br />

instruction using the SETUP key.<br />

Dispense delay times used at the start of the circle and at the end of the circle can be<br />

controlled by registering a Line Dispense Setup instruction in a previous memory<br />

address. The Line Dispense Setup instruction is registered by pressing the SETUP key.<br />

See also SECTION 5:5.1 Line Speed and SECTION 5:5.2 Line Dispense Setup.<br />

The upward motion of the tip after dispensing can be controlled by registering a Dispense<br />

End Setup instruction and / or a Z Clearance instruction in a previous memory address.<br />

Dispense End Setup and Z Clearance instructions are registered using the SETUP key.<br />

See also SECTION 5:5.4 Dispense End Setup and SECTION 5:5.5 Z Clearance.<br />

- Page 32 - © 2011 <strong>Fisnar</strong> Inc.