<strong>F4200N</strong> Operating <strong>Manual</strong><br />

Section 5: Point Type & Function Reference<br />

Part # 562187N<br />

Rev. C Jun 2011<br />

3.5 Lock or Unlock Program<br />

Lock or Unlock Program allows the user to protect a program <strong>fr</strong>om editing. If the program<br />

is locked, the user will not be able to change any of the program data. Unlocking the<br />

program will allow the data to be changed again.<br />

3.6 Password Setup<br />

Password Setup allows the password to be set or reset for the current program.<br />

To set the password, select F2 (MENU 1), Utility Menu, and Password Setup. The user<br />

will be prompted for a NEW PASSWORD. Type the new password and press ENTER.<br />

If the password is left blank and ENTER is pressed, the password will be removed. After<br />

changing or resetting the password, the robot power should be turned off.<br />

The purpose of the password is to protect the program <strong>fr</strong>om unauthorized editing. The<br />

user will not be allowed to enter TEACH mode unless the correct password is entered. If<br />

the password is forgotten, the master password (777) can be used to gain access to the<br />

program.<br />

3.7 Cycle Counter<br />

When in run mode, the first line of the display shows the number of program cycles, which<br />

have run to completion for the current program number: [RUN MODE][X]<br />

It is possible to reset this number by selecting F2 (MENU 1), Utility Menu, Cycle<br />

Counter. When prompted for the New Data: press 0 and ENTER to reset the cycle<br />

counter.<br />

It is also possible to cause an alarm to be generated after a fixed number of program<br />

cycles. Select F2 (MENU 1), Utility Menu, Cycle Counter. When prompted for the New<br />

Data: type the number of program cycles to complete before generating the alarm and<br />

press ENTER.<br />

In run mode, when the set number of program cycles has been completed, the display will<br />

show Counter Full [Shif+Enter] and by pressing the shift+enter buttons the robot will be<br />

disabled and you can run the program again.<br />

- Page 67 - © 2011 <strong>Fisnar</strong> Inc.