<strong>F4200N</strong> Operating <strong>Manual</strong><br />
Section 5: Point Type & Function Reference<br />
Part # 562187N<br />
Rev. C Jun 2011<br />
2.11 Resume<br />
Once a program has been interrupted, the Resume setting will determine if the program<br />
restarts <strong>fr</strong>om point # 1 or <strong>fr</strong>om the point at which it was interrupted, such as the middle of a<br />
program.<br />
If Resume is set to 1 and a program is stopped by an emergency stop signal or by the<br />
enclosure door switch open signal, the program will restart <strong>fr</strong>om the point at which it was<br />
interrupted when the start button is pressed.<br />
If Resume is set to 2 and a program is stopped by an emergency stop signal or by the<br />
enclosure door switch open signal, the program will restart <strong>fr</strong>om point #1.<br />
The default value is 2.<br />