<strong>F4200N</strong> Operating <strong>Manual</strong><br />
Section 5: Point Type & Function Reference<br />
Part # 562187N<br />
Rev. C Jun 2011<br />
Instruction<br />
Display Shows<br />
3<br />
Press 1 to save the first location in temporary<br />
position #1. Then press ENTER<br />
4<br />
Jog the tip to the new, correct position for the<br />
second reference point.<br />
5<br />
Press the MENU 2 key, then select Save Temp<br />
Point to save the location. The display will<br />
prompt for the temporary point number to save.<br />
Save temp point<br />
--------------------------<br />
Point (1-9):<br />
Relocate Save To 1,2 Point<br />
6<br />
Press 2 to save the second location in temporary<br />
position #2. Then press ENTER<br />
7<br />
Press F2 (Menu 1), then 7. Utility Menu, and<br />
select Relocate Data.<br />
Relocate Data<br />
--------------------------<br />
1.All Points<br />
2.Some Points<br />
SELECT:<br />
8 Press 1 to select All Points. Then press ENTER<br />
Relocate All Point<br />
S1-><br />
S2-><br />
9<br />
Type 3 and press ENTER to designate memory<br />
address number 3 as reference point 1 (temp<br />
point #1).<br />
Relocate All Point<br />
S1->3<br />
S2-><br />
10<br />
Type 4 and press ENTER to designate memory<br />
address number 4 as reference point 2 (temp<br />
point #2).<br />
Relocate All Point<br />
S1->3<br />
S2->4<br />
11<br />
The program location will be adjusted for X<br />
offset, Y offset and angle of rotation.<br />
- Page 66 - © 2011 <strong>Fisnar</strong> Inc.