07.06.2015 Views

F4200N Manual - Fisnar.fr

F4200N Manual - Fisnar.fr

F4200N Manual - Fisnar.fr

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>F4200N</strong> Operating <strong>Manual</strong><br />

Section 5: Point Type & Function Reference<br />

Part # 562187N<br />

Rev. C Jun 2011<br />

5. F4 (Setup Menu)<br />

Below is a list of functions, which are found under the SETUP key. These functions are all<br />

related to the setup of dispensing parameters.<br />

5.1 Line Speed<br />

Registers the line speed used for all lines <strong>fr</strong>om the current memory address forward until<br />

another Line Speed instruction is found.<br />

5.2 Line Dispense Setup<br />

When dispensing high viscosity materials, there is often a delay <strong>fr</strong>om the moment the<br />

dispenser is turned on until the material begins to flow. The following parameters are set<br />

under this function: Head Time, Tail Time, Node Time and Tail Length.<br />

The Head Time setting is a delay time used at the start of line dispensing to prevent the<br />

tip <strong>fr</strong>om moving along the line path until the material is flowing. The tip will move to the<br />

start of the line, turn on the dispenser and wait for the time period specified in the head<br />

time setting before moving. The time value can be adjusted to ensure that the material<br />

begins flowing at the same time as the line movement begins.<br />

At the end of dispensing, a delay is often required after the dispenser is turned off, to allow<br />

the barrel pressure to equalize, before moving to the next point location. This prevents<br />

material <strong>fr</strong>om being „spilled‟ where it is not wanted. This time delay at the end of<br />

dispensing is called the Tail Time.<br />

The Node Time parameter enters a wait time that only affects the Line Passing<br />

command. Tip will pass through line passing point and will wait at line passing point with<br />

the dispenser activated for the time specified in the Node Time.<br />

Usually the material continues flowing after the dispenser is off, due to pressure built in<br />

the system. Tail Length automatically turns off the dispenser at a user defined distance<br />

before the end of a line, preventing excess of material to be deposited at the end of the<br />

line.<br />

- Page 72 - © 2011 <strong>Fisnar</strong> Inc.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!