YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

GSM Radio Module <strong>CSI</strong>-F-<strong>10</strong> Page 859.2.8 Error EventError handling can be implemented with the function Error event.The Boolean output is switched to "1" when an error condition ispresent. The output is switched back to "0" if the error disappears.The type of error event can be set with the Event parameter.The following events are possible:Below signal rangeA sensor has a cable break, for exampleAbove signal rangeThe signal of one sensor is above the signal rangeIncorrect sensor constellationThere is either no sensor, or an incorrect sensor connected to onesensor connection port.Numerical errorAn error occured during a calculation, e.g. division by 0 or squareroot of a negative number, logarithm of 0, etc.Cycle time exceededThe set cycle time was exceeded.Inputs: -Outputs: y: (Boolean)Parameters: p 1 : Event (input list)9.2.9 Boolean ConstantsThe Boolean Constant function supplies a Boolean value which isdefined in the Editor and which does not change during the runningtime. That means that the parameter entered in the Editor is outputduring the running time at the output.Inputs: -Outputs: y: (Boolean)Parameters: p 1 : Value (Boolean)Status 2011/08/17 HYDAC ELECTRONIC GMBH Part.-Nr.: 669752