13.07.2015 Views

Intel® Server System Server System "Emerald Ridge ... - CTL

Intel® Server System Server System "Emerald Ridge ... - CTL

Intel® Server System Server System "Emerald Ridge ... - CTL

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Intel® <strong>Server</strong> <strong>System</strong> "<strong>Emerald</strong> <strong>Ridge</strong>” Integrated Baseboard Management Controller EPSIPMI Command InterfaceNet Function = Storage (0Ah), , LUN = 00CodeCommandRequest, Response Data22h Reserve SDR Repository Per the Intelligent Platform Management Interface SpecificationSecond Generation v2.023h Get SDR Per the Intelligent Platform Management Interface SpecificationSecond Generation v2.024h Add SDR Per the Intelligent Platform Management Interface SpecificationSecond Generation v2.025h Partial Add SDR Per the Intelligent Platform Management Interface SpecificationSecond Generation v2.026h Delete SDR Not implemented27h Clear SDR Repository Per the Intelligent Platform Management Interface SpecificationSecond Generation v2.028h Get SDR Repository Time Per the Intelligent Platform Management Interface SpecificationSecond Generation v2.029h Set SDR Repository Time Not implemented2Ah Enter SDR Repository Update mode Per the Intelligent Platform Management Interface SpecificationSecond Generation v2.02Bh Exit SDR Repository Mode Per the Intelligent Platform Management Interface SpecificationSecond Generation v2.02Ch Run Initialization Agent Per the Intelligent Platform Management Interface SpecificationSecond Generation v2.0Table 50. BMC SEL Device CommandsNet Function = Storage (0Ah), , LUN = 00CodeCommandRequest, Response Data40h Get SEL Info Per the Intelligent Platform Management Interface Specification SecondGeneration v2.041h Get SEL Allocation Info Per the Intelligent Platform Management Interface Specification SecondGeneration v2.042h Reserve SEL Per the Intelligent Platform Management Interface Specification SecondGeneration v2.043h Get SEL Entry Per the Intelligent Platform Management Interface Specification SecondGeneration v2.044h Add SEL Entry Per the Intelligent Platform Management Interface Specification SecondGeneration v2.045h Partial Add SEL Entry Not implemented46h Delete SEL Entry Not implemented47h Clear SEL Per the Intelligent Platform Management Interface Specification SecondGeneration v2.048h Get SEL Time Per the Intelligent Platform Management Interface Specification SecondGeneration v2.049h Set SEL Time Per the Intelligent Platform Management Interface Specification SecondGeneration v2.05Ah Get Auxiliary Log Status Not implemented5Bh Set Auxiliary Log Status Not implementedRevision 1.1Intel ® Confidential 101

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!