13.07.2015 Views

Intel® Server System Server System "Emerald Ridge ... - CTL

Intel® Server System Server System "Emerald Ridge ... - CTL

Intel® Server System Server System "Emerald Ridge ... - CTL

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Intel® <strong>Server</strong> <strong>System</strong> "<strong>Emerald</strong> <strong>Ridge</strong>” ” Integrated Baseboard Management Controller EPS 錯 誤 ! 尚 未 定 義 樣 式 。Table 32. Factory Configured PEF Table Entries.Event FilterOffset MaskEventsNumber1 Non-critical, critical and non-recoverable Temperature sensor out of range2 Non-critical, critical and non-recoverable Voltage sensor out of range3 Non-critical, critical and non-recoverable Fan failure4 General chassis intrusion Chassis intrusion (security violation)5 Failure and predictive failure Power supply failure6 Uncorrectable ECC BIOS7 POST error BIOS: POST code error8 FRB2 Watchdog Timer expiration for FRB29 – Reserved (not preconfigured; reserved for future use)10 Power down, power cycle, and reset Watchdog timer11 OEM system boot event <strong>System</strong> restart (reboot)12 – Reserved (not preconfigured; reserved for future use)Additionally, the BMC supports the following PEF actions:• Power off• Power cycle• Reset• OEM action• AlertsThe “Diagnostic interrupt” action is not supported.4.9.13 LAN AlertingThe BMC supports sending embedded LAN alerts, called SNMP PET (Platform Event traps), aswell as SMTP email alerts.LAN Alert via Backup Gateway is not supported.The BMC supports a minimum of four LAN alert destinations.4.9.13.1 SNMP Platform Event Traps (PETs)This feature enables a target system to send SNMP traps to a designated IP address via LAN.These alerts are formatted per the Intelligent Platform Management Interface SpecificationSecond Generation v2.0. A MIB file associated with the traps is provided with the BMC FW tofacilitate interpretation of the traps by external SW.The format of the MIB file is covered under RFC 2578.4.9.14 Alert Policy TableAssociated with each PEF entry is an alert policy that determines which IPMI channel the alertis to be sent. There is a maximum of 120 alert policy entries. There are no pre-configuredentries in the alert policy table because the destination types and alerts may vary by user. Eachentry in the alert policy table contains 4 bytes for a maximum table size of 80 bytes.Revision 1.1Intel ® Confidential 71

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!