13.07.2015 Views

Intel® Server System Server System "Emerald Ridge ... - CTL

Intel® Server System Server System "Emerald Ridge ... - CTL

Intel® Server System Server System "Emerald Ridge ... - CTL

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SMM CommandsIntel® <strong>Server</strong> <strong>System</strong> "<strong>Emerald</strong> <strong>Ridge</strong>” Integrated Baseboard Management Controller EPS12. SMM CommandsThe BMC supports the following commands via the SMM interface.Table 75. SMM CommandsNetFnCommandDescriptionDetailNumberApp (06h) 01h Get Device ID Per the Intelligent PlatformManagement Interface SpecificationSecond Generation v2.0.App (06h) 06h Set ACPI Power State Per the Intelligent PlatformManagement Interface SpecificationSecond Generation v2.0.App (06h) 07h Get ACPI Power State Per the Intelligent PlatformManagement Interface SpecificationSecond Generation v2.0.App (06h) 2Eh Set BMC Global Enables Per the Intelligent PlatformManagement Interface SpecificationSecond Generation v2.0.App (06h) 2Fh Get BMC Global Enables Per the Intelligent PlatformManagement Interface SpecificationSecond Generation v2.0.App (06h) 30h Clear Message Flags Per the Intelligent PlatformManagement Interface SpecificationSecond Generation v2.0.App (06h) 31h Get Message Flags Per the Intelligent PlatformManagement Interface SpecificationSecond Generation v2.0.App (06h) 35h Read Event Message Buffer Per the Intelligent PlatformManagement Interface SpecificationSecond Generation v2.0.App (06h) 3Dh Get Session Info Per the Intelligent PlatformManagement Interface SpecificationSecond Generation v2.0.App (06h) 4Ah Get Payload ActivationStatusPer the Intelligent PlatformManagement Interface SpecificationSecond Generation v2.0.App (06h) 4Bh Get Payload Instance Info Per the Intelligent PlatformManagement Interface SpecificationSecond Generation v2.0.Sensor (04h) 02h Platform Event Per the Intelligent PlatformManagement Interface SpecificationSecond Generation v2.0.Storage (0Ah) 44h Add SEL Entry Per the Intelligent PlatformManagement Interface SpecificationSecond Generation v2.0.Storage (0Ah) 48h Get SEL Time Per the Intelligent PlatformManagement Interface SpecificationSecond Generation v2.0.Storage (0Ah) 49h Set SEL Time Per the Intelligent PlatformManagement Interface SpecificationSecond Generation v2.0.134Intel ConfidentialRevision 1.1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!