13.07.2015 Views

Intel® Server System Server System "Emerald Ridge ... - CTL

Intel® Server System Server System "Emerald Ridge ... - CTL

Intel® Server System Server System "Emerald Ridge ... - CTL

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

錯 誤 ! 尚 未 定 義 樣 式 。Intel® <strong>Server</strong> <strong>System</strong> "<strong>Emerald</strong> <strong>Ridge</strong>” Integrated Baseboard Management Controller EPSTable 30. Supported RMCP+ Cipher SuitesIDAuthentication AlgorithmIntegrity Algorithm(s)Confidentiality Algorithm(s)0 1 RAKP-none None None1 RAKP-HMAC-SHA1 None None2 RAKP-HMAC-SHA1 HMAC-SHA1-96 None3 RAKP-HMAC-SHA1 HMAC-SHA1-96 AES-CBC-1286 RAKP-HMAC-MD5 None None7 RAKP-HMAC-MD5 HMAC-MD5-128 None8 RAKP-HMAC-MD5 HMAC-MD5-128 AES-CBC-12811 RAKP-HMAC-MD5 MD5-128 None12 RAKP-HMAC-MD5 MD5-128 AES-CBC-128Note:1. Cipher suite 0 defaults to callback privilege for security purposes. This may be changed by any administrator.For user authentication, the BMC can be configured with ‘null’ user names, whereby password /key lookup is done based on ‘privilege level only’, or with non-null user names, where the keylookup for the session is determined by user name.IPMI 2.0 messaging introduces payload types and payload IDs to allow data types other thanIPMI commands to be transferred. IPMI 2.0 serial-over-LAN is implemented as a payload type.Table 31. Supported RMCP+ Payload TypesPayload TypeFeatureIANA00h IPMI message N/A01h Serial-over-LAN N/A02h OEM explicit Intel (343)10h – 15h Session setup N/A4.9.3 RMCP / ASF MessagingThe BMC supports RMCP ping discovery in which the BMC responds with a pong message toan RMCP / ASF ping request. This is implemented per the Intelligent Platform ManagementInterface Specification Second Generation v2.0.4.9.4 BMC Embedded LAN ChannelsBMC hardware includes two dedicated 10/100 network interfaces,Interface 1: This interface is available from either of available NIC ports in system which can beshared with the host. Only one NIC may be enabled for management traffic at any time. Tochange the NIC enabled for management traffic, please use the “Write LAN Channel Port” OEMIPMI command. For more details on this command, please see Table 56.Interface 2: This interface is available from RMM3 which is dedicated management NIC and notshared with host.For these channels, support can be enabled for IPMI-over-LAN and DHCP.66Intel ConfidentialRevision 1.1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!