13.07.2015 Views

Intel® Server System Server System "Emerald Ridge ... - CTL

Intel® Server System Server System "Emerald Ridge ... - CTL

Intel® Server System Server System "Emerald Ridge ... - CTL

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

錯 誤 ! 尚 未 定 義 樣 式 。 EPSRevision HistoryDateRevOct 2009 .90 Merged with Thurley EPS 1.12ModificationsChanged DIMM mapping section for Set Fault Indication and Set Fan ControlConfiguration.Changed Memory Power Failure Monitoring sectionChanged sensors characteristics for “Memory Power Fail”Changed stand-by availability for DIMM and Millbrook sensors.Updated “<strong>System</strong> Status LED Indicator “ tableFixed formatting / broken header and footersUpdated Fan Redundancy Detection section.Updated Fan redundancy sensor with supported offsets.Updated chassis section with “Global Fan Fault LED”Table 70 updated to reflect new PS Redundancy Configuration.Updated FAN Redundancy sensor with IPMI supported offsets.Dec 2009 .95 Updated section 3.5.4 – Removed LCP support Corrected OEM Get Reading cmd in Table 51Updated Get SM Signal in command tableUpdated sensor table - Processor status sensor - Presence de-assertion supportremoved.Updated CPU offline/online section.Updated IOH2 offline/online section.Remove IOH1 and IOH2 thermal trip scanning in standby modeUpdated FAN domains table with correct CPU and IOH Numbers.Added CSS LED SectionUpdated section: Power Supply Failure ManagementUpdated section: <strong>Server</strong> Chassis Support for QSSC-S4RReplaced SxxxR platform name with QSSC 0- S4RAdded MDR sectionAdded IPMIMessaging flag behavior in User modelTracker Fixed:112795-Get FRU Inventory Area Info for HSBP get response 0xCB 110217-Processor, Memory Riser cards numbering is not consistent in EPS 0.3.109990- Verify alerting behavior via the backup gateway failed.112985- There is discrepancy between the Number of possible sessions BMCreturns and the actual session establishment.112873: The description of section ''<strong>Server</strong> Chassis Support for SxxxxER'' onEPS 0.9 should be modified.113045: Power supply fan didn't back to normal speed after issue command torearm it from failure status.112857: Enabled user count does not matchexpected value during user access test.111858: [SLV] RMM3: ME version not displayed when signed in as an 'Operator'.112825 - The SEL length in BMC EPS v0.09 violates the IPMI spec.Revision 1.1Intel ® Confidentialiii

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!