13.07.2015 Views

Intel® Server System Server System "Emerald Ridge ... - CTL

Intel® Server System Server System "Emerald Ridge ... - CTL

Intel® Server System Server System "Emerald Ridge ... - CTL

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

IPMI Command InterfaceIntel® <strong>Server</strong> <strong>System</strong> "<strong>Emerald</strong> <strong>Ridge</strong>” Integrated Baseboard Management Controller EPSCode15h18hCommandSet SM Signal Request:Write LANChannel PortNet Function = Intel General Application (0x30), LUN = 00Request, Response DataDescriptionFor fan tachometer reading request (0Fh): only "Sample" action. BMC will return 0xC1Bit_0:complete code for all other values in Byte 03(action)0 – Fan presence sensor is unavailable1 – Fan presence sensor is availableBit_1: (valid only if Bit_0 is 1)0 – Fan is not present1 – Fan is presentByte 3 – Optional valueFor fan tachometer reading request (0Fh):Pulses per minute measured by the fantachometer. Contains the lower byte of the value.Byte 4 – Optional valueFor fan tachometer reading request (0Fh):Pulses per minute measured by the fantachometer. Contains the upper byte of thevalue.Byte 1 – Signal type00h – Power LED (Not supported)01h – <strong>System</strong> fault LED (Amber)02h – Cluster LED (Not supported)03h – HDD fault LED (Not supported)04h – Cooling fault LED (Not supported)05h – Fan power (Sets PWM value)06h – Power request (Not supported)07h – Sleep request (Not supported)08h – ACPI SCI (Not supported)09h – Speaker (Not supported)0Ah – Fan fail LED (Not supported)0Bh – CPU fail LED (Not supported)0Ch – DIMM fail LED (Not supported)0Dh – Identify LED0Eh – HDD activity LED (Not supported)0Fh – <strong>System</strong> ready LED (Green system statusLED)Byte 2 – Signal instance, zero-basedByte 3 – Action0 – Force de-asserted1 – Force asserted2 – RevertByte 4 – Optional value, used by multi-value signalsFor fan power/drive set request (05h), accepts0-64h – The actual % value of the PWM driveResponse:Byte 1 – Completion codeRequest:Byte 1 — Port numberAllows the real-time state of some outputsignals, like LEDs, to be set without losing theBMC internal state associated with the signals.The command allows the output signals torevert to their normal behavior. See Table 20.Certain signals take analog values or complexstates. The fourth byte of the request issupported for these types of signals. See fanpower in Table 20.Instance values for signal type 05h aredomain-based.Note: For Signal Type 05h, the number ofinstances (PWMs) is system-dependent.Allows the user to select which LAN channelBMC LAN traffic can communicate with. Thisport value will be saved in the bootloader108Intel ConfidentialRevision 1.1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!