13.07.2015 Views

Intel® Server System Server System "Emerald Ridge ... - CTL

Intel® Server System Server System "Emerald Ridge ... - CTL

Intel® Server System Server System "Emerald Ridge ... - CTL

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Intel® <strong>Server</strong> <strong>System</strong> "<strong>Emerald</strong> <strong>Ridge</strong>” Integrated Baseboard Management Controller EPSBIOS-BMC BMC Interactions8. BIOS-BMC BMC InteractionsBIOS-BMC interactions include the following:FRB2 Operation.POST Complete Signaling – BIOS asserts the POST Complete signal at the end of POST.BMC firmware monitors this signal.Retrieval of Platform Information – BIOS may query firmware revisions for the BMC andattached satellite controllers. BIOS may also read FRU device locator records from the BMC,to determine the system’s inventory. Additionally, BIOS must use subsystem information topopulate SMBIOS tables.<strong>System</strong> GUID Information – BIOS must send system GUID to the BMC on boot.SEL – The BIOS may add entries to the BMC’s system event log.Power Restore Policy – BIOS may operate on the BMC’s power restore policy to supportBIOS setup functionality.ACPI – BIOS must notify the BMC of ACPI state changes.Front Panel Lockout – BIOS may operate on the BMC’s front-panel lockout to support BIOSsetup functionality.Serial Port Sharing – BIOS must interact with the BMC to share the serial port for systemuse.Serial Console Redirection – BIOS redirects serial output to the BMC, for LAN-based serialredirection.BMC Self Test/Health – BIOS may query the BMC for self test results.Clock Synchronization – BIOS must synchronize the BMC’s clock with the system clockusing the Set SEL Time IPMI command.BIOS-monitored sensors – BIOS must notify the BMC of system faults such as DIMMfailures using OEM IPMI commands. The BMC uses this information to control theassociated fault LEDs.BIOS must read the thermal profile data records from the BMC to determine appropriatethermal settings.BIOS may clear the SEL, per BIOS setup options.BIOS must bridge host information to the ME, through the BMC.BMC may interact with BIOS if a Set <strong>System</strong> Boot Options command requires altering theboot order.BIOS may query the BMC for board SKU and revision ID values.During Memory Hot Plug/Memory Online operation BIOS needs to send new DIMMpopulation order to BMC, Memory Hot Plug and Memory Offline/Online section for detail.Revision 1.1Intel ® Confidential 81

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!