13.07.2015 Views

Intel® Server System Server System "Emerald Ridge ... - CTL

Intel® Server System Server System "Emerald Ridge ... - CTL

Intel® Server System Server System "Emerald Ridge ... - CTL

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

錯 誤 ! 尚 未 定 義 樣 式 。Intel® <strong>Server</strong> <strong>System</strong> "<strong>Emerald</strong> <strong>Ridge</strong>” Integrated Baseboard Management Controller EPS4.9.7 Address Resolution Protocol (ARP)The BMC can receive and respond to ARP requests on BMC NICs; Gratuitous ARPs aresupported and disabled by default.4.9.8 Internet Control Message Protocol (ICMP)The BMC supports the following ICMP message types targeting the BMC over integrated NICs:Echo request (ping): The BMC sends an Echo Reply.Destination unreachable: If message is associated with an active socket connection withinthe BMC, the BMC closes the socket.4.9.9 Virtual Local Area Network (VLAN)Not supported4.9.10 Secure Shell (SSH)Secure Shell (SSH) connections are supported for SMASH-CLP sessions to the BMC.4.9.11 Serial-overover-LAN (SOL 2.0)The BMC supports IPMI 2.0 SOL.IPMI 2.0 introduced a standard serial-over-LAN feature. This is implemented as a standardpayload type (01h) over RMCP+.Three commands are implemented for SOL 2.0 configuration.“Get SOL 2.0 Configuration Parameters” and “Set SOL 2.0 Configuration Parameters”:These commands are used to get and set the values of the SOL configuration parameters.The parameters are implemented on a per-channel basis. See Table 62.“Activating SOL”: This command is not accepted by the BMC. It is sent by the BMC whenSOL is activated, to notify a remote client of the switch to SOL.Activating a SOL session requires an existing IPMI-over-LAN session. If encryption is used, itshould be negotiated when the IOL session is established. SOL sessions are only supported onserial port 1 (COM1).4.9.12 Platform Event Filter (PEF)The BMC includes the ability to generate a selectable action, such as a system power-off orreset, when a match occurs to one of a configurable set of events. This capability is calledPlatform Event Filtering, or PEF. One of the available PEF actions is to trigger the BMC to senda LAN alert to one or more destinations.The BMC supports 20 PEF filters. The first twelve entries in the PEF filter table arepreconfigured (but may be changed by the user). The remaining entries are left blank, and maybe configured by the user.70Intel ConfidentialRevision 1.1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!