Programming and Parameters 3-69NameNo. Description505 PM TestWait TimeDefines the time interval used for the automated measurement of Par 504 [PM AbsEncdOffst] for a Permanent Magnet (PM) motor.506 PM Test Idc RampDefines the ramp rate of the Flux Producing (d-axis) current reference that is used for theautomated measurement of Par 504 [PM AbsEncd Offst] for a Permanent Magnet (PM)motor.507 PM Test FreqRampDefines the ramp rate of the frequency reference that is used for the automatedmeasurement of Par 504 [PM AbsEncd Offst] for a Permanent Magnet (PM) motor.508 PM Test Freq RefDefines the frequency reference that is used for the automated measurement of Par 504[PM AbsEncd Offst] for a Permanent Magnet (PM) motor.509 PM Test I RefDefines the amplitude of the Flux Producing (d-axis) current reference that is used for theautomated measurement of Par 504 [PM AbsEncd Offst] for a Permanent Magnet (PM)motor.ValuesUnits: mSecDefault: 2000Min/Max: 500/5000Units:Default:Min/Max:Scale:Units:Default:Min/Max:Scale:%/mS0.10.0/195.3x 10%/mS0.10.0/195.3x 10Units: %Default: 10.0Min/Max: -/+799.9Scale: x 10Units: %Default: 30.0Min/Max: 0.0/799.9Scale: x 10510 FVC Mode ConfigConfigures Field Oriented Control (FOC) operation.Notes: Bit changes were made for firmware version 2.03. Bits 10 and 11 were added for firmware version 3.01.LinkableRead-WriteData TypeRW 16-bitIntegerRW 16-bitIntegerRW 16-bitIntegerRW 16-bitIntegerRW 16-bitInteger!ATTENTION: Do not modify this parameter.Motor/<strong>Drive</strong> instabilities and damage couldresult.OptionsReservedReservedReservedReservedReservedReservedReservedReservedReservedSrLss RdThruVltMinorLpEnSoftAdptGainReservedReservedReservedReservedLwSpdRflctWvSlip Reg EnSlipGain EstReservedSlipPrloadEnSlipSlewRtEnReflWaveCompBusGain CompReservedFlux Reg UseFlux Reg EnReservedReservedReservedReservedReservedDefault 0 0 0 0 0 0 0 0 1 0 1 0 0 0 0 0 0 1 1 0 0 0 1 1 0 1 1 0 0 0 0 0Bit 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = False1 = True511 FVC2 Mode ConfigConfigures Field Oriented Control - 2 (FOC2) operation.Notes: Bit changes were made for firmware version 2.03. This parameter was changed to non-linkable for firmware version 3.01.!ATTENTION: Do not modify this parameter.Motor/<strong>Drive</strong> instabilities and damage couldresult.OptionsLnfSnsr DirLnfSnsr UseReservedFlxRatRf UseNTC ActiveReservedReservedCEMF We UseReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedBusGain CompReservedReservedReservedReservedReservedReservedReservedReservedDefault 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0Bit 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = False1 = True

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!