13.07.2015 Views

User Manual High Performance AC Drive

User Manual High Performance AC Drive

User Manual High Performance AC Drive

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

A-2 Supplemental InformationCategoryAgencyCertificationSpecificationFrames 1-6 (690V <strong>Drive</strong> frames 5 & 6 only)Frames 9 & upThe drive is designed to meet applicable requirements of the The drive is designed to meet applicable requirements of thefollowing codes/standards:following codes/standards:IEC 61800-2 Adjustable speed electrical power drive systems - IEC 61800-2 Adjustable speed electrical power drive systems -General requirementsGeneral requirementsIEC 61800-5-1 Adjustable speed electrical power drive systems IEC 61800-5-1 Adjustable speed electrical power drive systems- Safety requirements- Safety requirementsNFPA 70 – US National Electric CodeNFPA 70 - US National Electrical CodeNEMA 250 – Enclosures for Electrical EquipmentUL and cUL Listed to UL508C and CAN/CSA - 22.2 No. 14-95 UL and cUL Listed to UL508C and CAN/CSA - 22.2 No. 14-95U L USC ®..TUVRheinlandProduct SafetyEWCProduction inspectedMarked for all applicable European DirectivesEMC Directive (89/336/EEC)EmissionsEN 61800-3 Adjustable Speed electrical power drivesystems Part 3ImmunityEN 61800-3 Second Environment, Restricted DistributionLow Voltage Directive (73/23/EEC)EN 50178 Electronic Equipment for use in PowerInstallationsTUV Rheinland (applies to frames 1 - 6, 200/400V, and frames 5& 6, 690V only)TUV Functional Safety Report only for frames 1 - 4, 600V (no FSmark on the label)Marked for all applicable European DirectivesEMC Directive (89/336/EEC)EmissionsEN 61800-3 Adjustable Speed electrical power drivesystems Part 3Low Voltage Directive (73/23/EEC)EN 50178 Electronic Equipment for use in PowerInstallationsTUV functional safety report only (no FS mark on the label)EN 50178Bauart geprüft..TUVRheinlandFunctionalSafetyType approvedEnvironment Altitude: 1000 m (3300 ft.) max. without derating 1000 m (3300 ft) max. without deratingSurrounding Air TemperatureBased on drive rating, refer to <strong>Drive</strong> Frame chapterswithout Derating:Open Type: 0 to 50° C (32 to 122° F)IP20: 0 to 50° C (32 to 122° F)NEMA Type 1: 0 to 40° C (32 to 104 ° F)IP56, NEMA Type 4X: 0 to 40 ° C (32 to 104 ° F)Note: Frames 9 & 10 are rated 0 to 40 ° C (32 to 104 ° F)surrounding air.Storage Temperature (all -40 to 70° C (-40 to 158° F) –40 to 70 degrees C (–40 to 158 degrees F)const.):Relative Humidity: 5 to 95% non-condensing 5 to 95% non-condensingShock: 10G peak for 11 ms duration (+/- 1.0 ms) 15G peak for 11ms duration (±1.0 ms)Vibration: 0.152 mm (0.006 in.) displacement, 1G peak, 5.5 Hz 2 mm (0.0787 in.) displacement, 1G peakEN50178 / EN60068-2-6AtmosphereImportant: <strong>Drive</strong> must not be installed in an area where the Important: <strong>Drive</strong> must not be installed in an area where theambient atmosphere contains volatile or corrosive gas, vapors or ambient atmosphere contains volatile or corrosive gas, vaporsdust. If the drive is not going to be installed for a period of time, it or dust. If the drive is not going to be installed for a period ofmust be stored in an area where it will not be exposed to acorrosive atmosphere.time, it must be stored in an area where it will not be exposed toa corrosive atmosphere.Electrical <strong>AC</strong> InputVoltage Tolerance:See Input Voltage Range/Tolerance on page C-1 for Full Powerand Operating RangeSee Input Voltage Range/Tolerance on page C-1 for Full Powerand Operating RangeFrequency Tolerance: 47-63 Hz 47-63 Hz.Input Phases:Three-phase input provides full rating for all drives. Single-phaseoperation provides 50% of rated current.Three-phase input provides full rating for all drives.Single-phase operation provides 50% of rated current.DC InputVoltage Tolerance +/- 10% of Nominal Bus Voltage (above) +/- 10% of Nominal Bus Voltage (above)Displacement Power Factor: 0.98 across speed range 0.98 across speed rangeEfficiency: 97.5% at rated amps, nominal line volts. 97.5% at rated amps, nominal line volts.Max. Short Circuit Current Maximum short circuit current rating to match specified fuse/ ≤ 200,000 AmpsRating:circuit breaker capability.Using Recommended Fuse ≤ 200,000 Ampsor Circuit Breaker TypeMaximum <strong>Drive</strong> to Motor Power The drive to motor rating cannot exceed a 2:1 ratioThe drive to motor rating cannot exceed a 2:1 ratioRatio

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!