3-46 Programming and ParametersLinkableRead-WriteData TypeNameNo. DescriptionValues320 Exception Event1Indicates the presence of certain drive anomalies. In some cases, you may configure the drive's response to these events by entering values in the parameters ofthe fault/alarm configuration group of the utility file.OptionsPWM AsynchroPrecharge ErMC FirmwarePWM ShortVPL/MC CommOverCurrentGround FaultTrans DesatBus OverVoltMC CommissnOver FreqInertia TestDSP ErrorDSP Mem ErrExt Fault InInv OL TripInv OL PendInv TempTripInv TempPendMotor StallMtr OL PendMtr OL TripPower LossSLink CommSLink HWCtrl EE MemFB Opt1 LossFB Opt0 LossEncdr1 LossEncdr0 LossSpdRef DecelAbs OverSpdDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = False1 = True321 Exception Event2Indicates the presence of certain drive anomalies. Configure the drive's response to these events by entering values in the parameters of the fault/alarmconfiguration group of the utility file.OptionsLgx LinkChngLgx ClosedLgx TimeoutLgx OutOfRunNetLoss DPI6NetLoss DPI5NetLoss DPI4NetLoss DPI3NetLoss DPI2NetLoss DPI1DPI Loss P6DPI Loss P5DPI Loss P4DPI Loss P3DPI Loss P2DPI Loss P1No Ctrl DevcMC CML FailInterp SynchEnableHealthNonCnfgAlarmVoltFdbkLossBusUnderVoltRidethruTimeSlink MultPowerEE CksmBrakeOL TripPSC Sys Flt2PSC Sys Flt1Ctrl EE CksmMC Command+/- 12v PwrDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = False1 = True322 Exception Event3Indicates the presence of certain drive anomalies. Configure the drive's response to these events by entering values in the parameters of the fault/alarmconfiguration group of the utility file.• Bit 11 [HH HW Ver] is sed to indicate a <strong>High</strong> Horsepower hardware version fault• Bit 12 [HH CurUnblnc] is used to indicate a <strong>High</strong> Horsepower output current unbalanced fault• Bit 13 [HH VltUnblnc] is used to indicate a <strong>High</strong> Horsepower Bus voltage unbalanced fault• Bit 29 [AnlgIn1 Loss] is used to indicate an Analog Input 1 loss fault• Bit 30 [AnlgIn2 Loss] is used to indicate an Analog Input 2 loss fault• Bit 31 [AnlgIn3 Loss] is used to indicate an Analog Input 3 loss faultNotes: Bits 16, 20 and 23 were added for firmware version 2.04. Bits 11, 12, 13, 29, 30 and 31 were added for firmware version 3.01.OptionsAnlgIn3 LossAnlgIn2 LossAnlgIn1 LossReservedReservedReservedReservedReservedNonCnfgAlarmReservedReservedPosit Err-Hrd OvrTrvl+Hrd OvrTrvl-Sft OvrTrvl+Sft OvrTrvlReservedReservedHH VltUnblncHH CurUnblncHH HW VerHH PwrBdTempHH PwrEE ErHHPrChrgCntcHH PwrBd PrcHH Drv OvrldHH FanFdbkLsHH BusWtchDgHH BusCRC ErHH BusLinkLsHH BusComDlyHH InPhaseLsDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = False1 = True323 Fault Status 1Indicates the occurrence of exception events that have been configured as fault conditions. These events are from Par 320 [Exception Event1].OptionsPWM AsynchroPrecharge ErMC FirmwarePWM ShortVPL/MC CommOverCurrentGround FaultGround FaultBus OverVoltMC CommissnOver FreqInertia TestDSP ErrorDSP Mem ErrExt Fault InInv OL TripInv OL PendInv OTmpTripInv OTmpPendMotor StallMtr OL PendMtr OL TripPower LossSLink CommSLink HWCtrl EE MemFB Opt1 LossFB Opt0 LossEncdr1 LossEncdr0 LossSpdRef DecelAbs OverSpdDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = False1 = True324 Fault Status 2Indicates the occurrence of exception events that have been configured as fault conditions. These events are from Par 321 [Exception Event2].OptionsLgx LinkChngLgx ClosedLgx TimeoutLgx OutOfRunNetLoss DPI6NetLoss DPI5NetLoss DPI4NetLoss DPI3NetLoss DPI2NetLoss DPI1DPI Loss P6DPI Loss P5DPI Loss P4DPI Loss P3DPI Loss P2DPI Loss P1No Ctrl DevcReservedReservedEnableHealthNon Cnfg AlarmVoltFdbkLossBusUnderVoltRidethruTimeSlink MultPowerEE CksmBrakeOL TripPSC Sys Flt2PSC Sys Flt1Ctrl EE CksmMC Command+/- 12v PwrDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = False1 = True

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!