C-6 Application NotesFigure C.4 <strong>Drive</strong> Operation When Par 154 [Stop Dwell Time] is Greater Than ZeroSpeedWhen Par 154 [Stop Dwell Time] is greater than zero, the drive delaysturning off the velocity and torque regulators for the amount of timespecified in Par 154.P 154 [Stop Dwell Time]P 160 [Zero Speed Lim]0 Time<strong>Drive</strong> Receives Stop CommandSetpt 1 DataProvides data for comparison of Par 172 [Setpt 1 Data] to Par 173 [Setpt1TripPoint], driving bit 16 [At Setpt 1] of Par 155 [Logic Status].Figure C.5 At Setpoint 1 StatusP172 [Setpt 1 Data]bit 16 [At Setpt 1] turns onbit 16 [At Setpt 1] turns offbit 16 [At Setpt 1] turns onbit 16 [At Setpt 1] turns offbit 16 [At Setpt 1] turns onbit 16 [At Setpt 1] turns offbit 16 [At Setpt 1] turns onbit 16 [At Setpt 1] turns offbit 16 [At Setpt 1] turns onbit 16 [At Setpt 1] turns off<strong>Drive</strong> Detects Zero Speed<strong>Drive</strong> Turns Off RegulatorsP173 [Setpt1 TripPoint] + 2 x P174 [Setpt 1 Limit]P173 [Setpt1 TripPoint] + P174 [Setpt 1 Limit]P173 [Setpt1 TripPoint]P173 [Setpt1 TripPoint] - P174 [Setpt 1 Limit]P173 [Setpt1 TripPoint] - 2 x P174 [Setpt 1 Limit]TimeSetpt 2 DataProvides data for comparison of Par175 [Setpt 2 Data] to Par 176 [Setpt2TripPoint], driving bit 17 [Above Setpt 2] of Par 155 [Logic Status].Figure C.6 Above Setpoint 2 StatusP175 [Setpt 2 Data]bit 17 [Above Setpt 2] turns onbit 17 [Above Setpt 2] turns offP176 [Setpt 2 TripPoint]P176 [Setpt 2 TripPoint] - P177 [Setpt 2 Limit]P176 [Setpt 2 TripPoint] - 2 x P177 [Setpt 2 Limit]0 Time

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!