T L | 7ANALISA DGA TERHADAP KINERJA TRANSFORMATOR 30 MVA GARDU INDUKBETUNG MENGGUNAKAN METODE FUZZYDjulil AmriJurusan Teknik Elektro Fakultas Teknik Universitas SriwijayaJalan Raya Prabumulih KM 32 Indralaya Ogan Ilir 30622 IndonesiaEmail : amfz_07@yahoo.co.idamfz_08@yahoo.comAbstrakPada penelitian ini, penulis menganalisa DGA (Dissolved Gas Analysis) terhadap kinerja transformator 30 MVAmenggunakan metode fuzzy, yang berada pada Gardu Induk Betung. DGA (Dissolved Gas Analysis) merupakananalisis gas terlarut pada minyak isolasi transformator dan merupakan salah satu bentuk perawatan untuk minyak isolasitransformator. Dalam menganalisa DGA menggunakan metode fuzzy IEC, dimana metode yang digunakan berbedadengan metode fuzzy pada umumnya, metode fuzzy ini tidak menggunakan defuzzyfikasi melainkan menormalisasikanhasil dari fire strength. Setelah didapatkan nilai dari normalisasi, maka nilai tersebut di masukkan dalam tabel indikasiFuzzy IEC. Tabel ini mengindikasikan secara detail apa yang terjadi dalam minyak isolasi. Selain menganalisa DGAdengan menggunakan metode fuzzy, pada penelitian ini membandingkan dengan metode IEEE yang di gunakan olehPT. PLN (Persero)Kata Kunci : Minyak Isolasi, DGA(Dissolved Gas Analysis),Metode IEEE dan Fuzzy IECAbstractIn this study, the authors analyzed the DGA ( Dissolved Gas Analysis ) of the 30 MVA transformerperformance using fuzzy method, which is at Betung substation. DGA (Dissolved Gas Analysis) is an analysis ofdissolved gases in transformer insulating oil, and is one form of treatment for transformer insulating oil.In analyzing the fuzzy method IEC DGA, which used different methods with fuzzy methods in general, this methoddoes not use defuzzyfikasi fuzzy but normalizing the results of fire strength. Having obtained the values of thenormalization, then the value is included in the table indicate Fuzzy IEC. This table indicates in detail whathappened in the insulating oil. In addition to analyzing DGA using fuzzy methods, this study compares the IEEEMethod that is used by used by the PT.PLN ( Persero )Keywords: Oil Insulation, DGA (Dissolved Gas Analysis), Methods IEEE and IEC Fuzzy1. Pendahuluan1.1 Latar BelakangTingginya kebutuhan akan listrik yang sangat tinggimembuat PT. PLN sebagai perusahaan yang bergerak dibidang penyedia kelistrikan Indonesia harus dapatmenyediakan kebutuhan listrik bagi masyarakat. Dalamsistem kelistrikan PT.PLN menyediakan SistemPembangkitan sebagai sumber untuk menghasilkan listrik,Gardu Induk merupakan simpul dalam sistem tenagalistrik, yang terdiri dari susunan dan rangkaian sejumlahperlengkapan yang dipasang menempati suatu lokasitertentu untuk menerima dan menyalurkan tenaga listrik,menaikkan dan menurunkan tegangan sesuai dengantingkat tegangan kerjanya, tempat melakukan kerjaswitching rangkaian suatu sistem tenaga listrik dan untukmenunjang keandalan sistem tenaga listrik. Salah satukomponen utama pada gardu induk adalah transformator ,pentingnya peranan transformator ini, maka perludilakukan penelitian yang berhubungan denganISBN: 978-602-97832-0-9SNTE-<strong>2012</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!