The energy efficiency in the use-phase is included in the parameter “Ey/FU (kWh/(y.lumen))”<br />

which reflects the yearly energy use (4000 h operation) per functional lumen.<br />

Different lamps found on the market within each family (e.g. HPS) were used with<br />

corresponding parameters.<br />

Table 62: Category F (Fast traffic) luminaires with HPS lamp<br />

parameter AVG<br />

lamp type HPS (BF) HPS (BF) HPS (TC) HPS (TC) HPS (TC) HPS<br />

Plamp (W) 250 250 250 250 250 250<br />

tgroup (y) 4 4 4 4 4 4<br />

light point distance (m) 50 50 50 50 50 50<br />

type.<br />

ηlamp (lm/W) 124 124 132 104 132 123<br />

LLMF 0,95 0,95 0,95 0,95 0,95 0,95<br />

LSF 0,94 0,94 0,94 0,94 0,94 0,94<br />

ηballast 91% 91% 91% 91% 91% 91%<br />

Lamp unit cost € 20 20 20 18 20 20<br />

Ballast unit cost € 40 40 40 40 40 40<br />

luminaire type OP OM OM CH CH<br />

IP 22 54 54 65 65<br />

UF 0,37 0,40 0,40 0,54 0,54 0.45<br />

LMF 0,51 0,78 0,78 0,85 0,85 0.75<br />

ULOR 1,5% 2,8% 2.8% 1,5% 1,5%<br />

DLOR 68,4% 66,6 66.6% 83,5% 83,5%<br />

Luminaire unit cost € 180 200 205 220 220 205<br />

Ey/FU (kWh/(y.lumen)) 0,21 0,13 0,12 0,10 0,08<br />

Table 63: Category F (Fast traffic) luminaires with LPS lamp<br />

parameter AVG<br />

lamp type LPS LPS LPS<br />

Plamp (W) 131 131 131<br />

tgroup (y) 3 3 3<br />

light point distance (m) 35 35 35<br />

type.<br />

ηlamp (lm/W) 198 198 198<br />

LLMF 0,87 0,87 0,87<br />

LSF 0,62 0,62 0,62<br />

ηballast 87% 87% 87%<br />

Lamp unit cost € 48 48 48<br />

Ballast unit cost € 77 77 77<br />

luminaire type CM CM<br />

IP 54 65<br />

UF 0,33 0,33 0.33<br />

LMF 0,82 0,87 0.84<br />

ULOR 3,6 3,6 3,6<br />

DLOR 66,4 66,4 66,4<br />

Luminaire unit cost 505 565 535<br />

Ey/FU<br />

(kWh/(y.lumen))<br />

0,10 0,10<br />

137