1.1.2 Performance requirements and <strong>street</strong> <strong>lighting</strong> categories<br />

Performance requirements for new <strong>street</strong> <strong>lighting</strong> installations are drawn up by CEN TC<br />

169/226 JWG in standard EN 13201-2. Note that in the installed base or stock of <strong>street</strong> <strong>lighting</strong>,<br />

older equipment do not necessarily meet these relatively new performance requirements e.g.<br />

<strong>lighting</strong> level, uniformity etc.. Determination of real-life performance versus standard<br />

performance is part of this study (chapter 3).<br />

Guideline CEN/TR 13201-1 specifies the selection of <strong>lighting</strong> classes for road <strong>lighting</strong>. This<br />

guideline considers the <strong>lighting</strong> classes set out in EN 13201-2 and provides guidance on the<br />

application of these classes. To do this, it includes a system to define an outdoor public traffic<br />

area in terms of parameters relevant to <strong>lighting</strong>. To assist in the application of classes, it<br />

suggests a practical relationship between the various series of <strong>lighting</strong> classes, in terms of<br />

comparable or alternative classes.<br />

The standard EN 13201-2 contains performance requirements in defined classes (ME1..ME6,<br />

MEW1..MEW6, CE0..CE5, S1..S6, ES1 .. ES6, A1 .. A6 ). A <strong>lighting</strong> class is characterized by<br />

a set of photometric requirements aiming at the visual needs of certain road users in certain<br />

types of road areas and environment.<br />

Because the number of classes specified in the standard is relatively extensive, a simplified and<br />

more aggregated classification of 3 road categories (see figure 8) is followed in this study..<br />

These categories with the same <strong>lighting</strong> levels and more corresponding with the classes used in<br />

European statistics for road lengths are defined hereafter:<br />

1. Category F “fast traffic” with fast motorized traffic use only, having only luminance<br />

requirements (cd/m²). Also corresponding to classes ME1 to ME5 or MEW1 to MEW5 for<br />

new installations.<br />

2. Category M “mixed traffic” with motorized traffic, slow moving vehicles, and possibly<br />

cyclists and pedestrians with only luminance requirements (cd/m² ). Also corresponding to<br />

classes ME2 to ME5 or MEW2 to MEW5 for new installations.<br />

3. Category S “slow traffic” for mainly urban and pedestrian areas, with illuminance<br />

requirements only (lx). Corresponding to classes CE0 to CE5, S1 to S6 and ES, EV and A<br />