and 0,41 lamps/yr per HPM luminaire. This gives an average of 0,31 lamps/yr per BaseCase<br />

luminaire, category M.<br />

The installed power per luminaire is 421 W for HPM and 169 W for HPS (taking into account<br />

lamp power, ballast efficiency and ballast maintenance factor, see chapter 4 for technical<br />

parameters). This gives an average of 246 W per BaseCase luminaire, category M.<br />

The functional light output for the HPS luminaire is 4357 lm, for the HPM luminaire this is<br />

3369 lm. This gives an average of 4055 lm per BaseCase luminaire, category M.<br />

Category S<br />

Road category S is lit with approximately 53% HPS, 31% HPM, 13% CFL and 4% MH<br />

BaseCase Luminaires and again all averages are weighed accordingly.<br />

All luminaires are equipped with electromagnetic ballasts that last an entire luminaire life,<br />

meaning 30 years.<br />

Taking the technical service life of these lamps into account and the lamp survival factor, LSF<br />

(see chapter 4), this results in an annual lamp replacement of 0,41 lamps/yr for HPM, 0,27<br />

lamps/yr for HPS, 0,35 lamps/yr for CFL and 0,53 lamps/yr for MH luminaires. This gives an<br />

average of 0,33 lamps/yr per BaseCase luminaire, category S.<br />

The installed power per luminaire is 83 W for HPS, 137 W for HPM, 45 W for CFL and 83 W<br />

for CMH (taking into account lamp power, ballast efficiency and ballast maintenance factor,<br />

see chapter 4 for technical parameters). This gives an average of 95 W per BaseCase luminaire,<br />

category S.<br />

The functional light output for the HPS luminaire is 1327 lm, for the HPM luminaire this is 897<br />

lm, for the CFL this is 319 lm, for the CMH luminaire this is 1000 lm. This gives an average of<br />

1054 lm per BaseCase luminaire, category S.<br />