Table 86: Life Cycle Impact, Base Case, Category M (per 1000 functional lumen)<br />

8<br />

9<br />

TOTAL (per 1000 functional lm)<br />

Other Resources & Waste<br />

169<br />

WEIGHTED<br />

AVERAGE<br />

HPM HPS<br />

Total Energy (GER) MJ 80.877 166.464 51.750<br />

of which, electricity (in primary MJ) MJ 80.433 165.861 51.360<br />

10 Water (process) ltr 5.388 11.084 3.450<br />

11 Water (cooling) ltr 214.438 442.224 136.916<br />

12 Waste, non-haz./ landfill g 99.933 201.630 65.323<br />

13 Waste, hazardous/ incinerated g 2.305 4.284 1.632<br />

Emissions (Air)<br />

14 Greenhouse Gases in GWP100 kg CO2 eq. 3.542 7.282 2.269<br />

15 Ozone Depletion, emissions mg R-11 eq. negligible negligible negligible<br />

16 Acidification, emissions g SO2 eq. 20.870 42.923 13.365<br />

17 Volatile Organic Compounds (VOC) g 31 64 20<br />

18 Persistent Organic Pollutants (POP) ng i-Teq 556 1.131 361<br />

19 Heavy Metals to Air mg Ni eq. 1.540 3.036 1.031<br />

PAHs mg Ni eq. 234 419 172<br />

20 Particulate Matter (PM, dust) g 524 1.016 356<br />

Emissions (Water)<br />

21 Heavy Metals to Water mg Hg/20 571 1.125 382<br />

22 Eutrophication g PO4 4 7 3<br />

23 Persistent Organic Pollutants (POP) ng i-Teq negligible negligible negligible<br />

When comparing the Base Case HPM and HPS luminaires from a total life cycle perspective,<br />

impacts per functional lumen output are substantially higher for HPM luminaires compared to<br />

HPS luminaires (a factor 3 for almost all impact categories).